Technical Information
Item condition |
New |
Manufacture name |
SIRIUS soft starter 200-600 V 570 A... |
Brand |
Siemens
|
Categories |
Control gear
|
Country of origin |
CZ |
Harmonized System Code |
8537 1098 00
|
Function |
Single direction |
With display |
No |
Rated operating voltage Ue |
200-600 V |
Rated control supply voltage at AC 50 Hz |
24 V |
Rated control supply voltage at AC 60 Hz |
24 V |
Rated control supply voltage at DC |
24 V |
Rated operation current Ie at 40 °C Tu |
570 A |
Rated power three-phase motor, inline, at 230 V |
160 kW |
Rated power three-phase motor, inline, at 400 V |
315 kW |
Rated power three-phase motor, inside delta, at 230 V |
315 kW |
Rated power three-phase motor, inside delta, at 400 V |
560 kW |
Rated surrounding temperature without derating |
40 °C |
Integrated motor overload protection |
Yes |
Voltage type for actuating |
AC/DC |
Internal bypass |
Yes |
Torque control |
No |
Packing details
Packing level 1 |
4047621038193 |
Description
SIRIUS soft starter 200-600 V 570 A, 24 V AC/DC spring-type terminals Analog output Soft starter SIRIUS 3RW52 General Performance for simple applications for soft starting and stopping of three-phase asynchronous motors.
Soft starting, reduction of current peaks, prevention of supply voltage fluctuations during startup, reduction of load on the power supply network, reduction of mechanical load in the drive, considerable saving of space and wiring compared to star-delta (wye-delta) starters and frequency converters, maintenance-free switching and extremely easy handling. The integrated bypass allows a very compact construction, saves energy and ensures low heat dissipation in the control cabinet. Intelligent monitoring functions protect the soft starter against overheating and the motor against overload. In addition, you can limit the current during startup to a settable maximum value. Thanks to 3-phase control, particularly suitable for high motor outputs and inside-delta circuits. The innovative Soft Torque function ensures that the motor is started gently. With the integrated remote reset, you can quickly and easily clear faults from a remote location. Worldwide approvals (e.g. IEC and UL/CSA).
The General Performance 3RW52 soft starters are available for supply systems up to 600 V in a wide performance range up to 560 kW with 24 V or 110-250 V supply voltages and all with both screw and spring-type terminals. Different device versions are available for analog output and thermistor motor protection.
Optional plug-in communication modules allow connection via PROFINET, PROFIBUS and Modbus TCP. Various HMI modules are available for installation in the device or the control cabinet door.
SIRIUS 3RW5 soft starters - As flexible as your tasks.