Register to unlock your exclusive B2B prices and start shopping. Sign up now!
Soft starter, 304 A, 200 - 690 V AC, Us= 24 V DC, with control unit and pump algorithm, for 690-V grids, Frame size T image 1
Soft starter, 304 A, 200 - 690 V AC, Us= 24 V DC, with control unit and pump algorithm, for 690-V grids, Frame size T image 2
Soft starter, 304 A, 200 - 690 V AC, Us= 24 V DC, with control unit and pump algorithm, for 690-V grids, Frame size T image 3
Soft starter, 304 A, 200 - 690 V AC, Us= 24 V DC, with control unit and pump algorithm, for 690-V grids, Frame size T image 4
Soft starter, 304 A, 200 - 690 V AC, Us= 24 V DC, with control unit and pump algorithm, for 690-V grids, Frame size T thumbnail 1
Soft starter, 304 A, 200 - 690 V AC, Us= 24 V DC, with control unit and pump algorithm, for 690-V grids, Frame size T thumbnail 2
Soft starter, 304 A, 200 - 690 V AC, Us= 24 V DC, with control unit and pump algorithm, for 690-V grids, Frame size T thumbnail 3
Soft starter, 304 A, 200 - 690 V AC, Us= 24 V DC, with control unit and pump algorithm, for 690-V grids, Frame size T thumbnail 4

Soft starter, 304 A, 200 - 690 V AC, Us= 24 V DC, with control unit and pump algorithm, for 690-V grids, Frame size T

In stock: No Vendor stock: No Minimal order quantity: 1
Price (excl. VAT):
4 335,92 €
This price is valid until 31.01.25
EAN: 4015081654871
MPN: 168992
Package: 1

Technical Information

Item condition New
Manufacture name Soft starter, 304 A, 200 - 690 V AC, Us= 24 V DC, with control unit and pump algorithm, for 690-V grids, Frame size T
Brand EATON
Categories Control gear
Country of origin DO
Function Single direction
With display Yes
Rated operating voltage Ue 200-690 V
Rated control supply voltage at AC 50 Hz 0 V
Rated control supply voltage at AC 60 Hz 0 V
Rated control supply voltage at DC 24 V
Degree of protection (IP) IP20
Release class Adjustable
Rated operation current Ie at 40 °C Tu 304 A
Rated power three-phase motor, inline, at 230 V 90 kW
Rated power three-phase motor, inline, at 400 V 160 kW
Rated power three-phase motor, inside delta, at 230 V 160 kW
Rated power three-phase motor, inside delta, at 400 V 250 kW
Rated surrounding temperature without derating 50 °C
Integrated motor overload protection Yes
Voltage type for actuating DC
Internal bypass Yes
Torque control No
Degree of protection (NEMA) Other

Packing details

Packing level 1 4015081654871

Description

Soft starter, Description: With internal bypass contacts, Function: Soft starter for three-phase loads, with control unit and pump algorithm, for 690-V grids, Mains supply voltage (50/60 Hz): ULN= 200 - 690 V AC, Supply voltage: Us= 24 V DC, Control voltage: UC= 24 V DC, Assigned motor rating (Standard connection, In-Line) at 400 V, 50 Hz: P= 160 kW, at 690 V, 50 Hz: P= 250 kW, at 460 V, 60 Hz: P= 250 HP, Rated operational current AC-53: Ie= 304 A, Startup class: CLASS 10 (star-delta replacement), CLASS 20 (heavy starting duty 3 x Ie for 45 s), CLASS 30 (6 x Ie for 30 s), Rated operational voltage: Ue= 200 V, 230 V, 400 V, 480 V, 600 V , 690 V, Connection to SmartWire-DT: no, Frame size: T, Ordering information: Terminal blocks for the terminals are required for frame sizes T, U, and V -> Accessories, Standards: IEC/EN 60947-4-2, UL 508, CSA22.2-14-1995, GB14048