Item condition |
New |
Manufacture name |
Spacer Module Passive light gray |
Brand |
WAGO
|
Categories |
Programmable logic controllers
|
Country of origin |
DE |
Harmonized System Code |
8538 9091 00
|
Width |
12 mm |
Height |
64 mm |
Depth |
100 mm |
Suitable for safety functions |
No |
Voltage type of supply voltage |
AC/DC |
Supporting protocol for LON |
No |
Number of HW-interfaces industrial Ethernet |
0 |
Number of HW-interfaces RS-232 |
0 |
Number of HW-interfaces RS-422 |
0 |
Number of HW-interfaces RS-485 |
0 |
Number of HW-interfaces serial TTY |
0 |
Number of HW-interfaces USB |
0 |
Number of HW-interfaces parallel |
0 |
Number of HW-interfaces other |
0 |
With optical interface |
No |
Supporting protocol for TCP/IP |
No |
Supporting protocol for ASI |
No |
Supporting protocol for PROFIBUS |
No |
Supporting protocol for CAN |
No |
Supporting protocol for INTERBUS |
No |
Supporting protocol for KNX |
No |
Supporting protocol for Modbus |
No |
Supporting protocol for Data-Highway |
No |
Supporting protocol for DeviceNet |
No |
Supporting protocol for SUCONET |
No |
Supporting protocol for other bus systems |
No |
With potential separation |
No |
Type of electric connection |
Spring clamp connection |
Rail mounting possible |
Yes |
Bus diagnosis possible |
No |
With power supply module |
No |
Explosion safety category for gas |
None |
Explosion safety category for dust |
None |
Fieldbus connection over separate bus coupler possible |
Yes |
Suitable as segment module |
Yes |
System accessory |
Yes |
Appendant operation agent (Ex ia) |
No |
Appendant operation agent (Ex ib) |
No |
Degree of protection (IP) |
IP20 |
Remote module |
No |
Supporting protocol for SERCOS |
No |
Supporting protocol for INTERBUS-Safety |
No |
Number of interfaces PROFINET |
0 |
Number of HW-interfaces Wireless |
0 |
Front built-in possible |
No |
Rack-assembly possible |
No |
Wall mounting/direct mounting |
No |
Radio standard Bluetooth |
No |
Radio standard Wi-Fi 802.11 |
No |
Supporting protocol for AS-Interface Safety at Work |
No |
Supporting protocol for DeviceNet Safety |
No |
Supporting protocol for EtherNet/IP |
No |
Supporting protocol for Foundation Fieldbus |
No |
Supporting protocol for PROFINET CBA |
No |
Supporting protocol for PROFINET IO |
No |
Supporting protocol for PROFIsafe |
No |
Supporting protocol for SafetyBUS p |
No |
Supply voltage AC 50 Hz |
0-230 V |
Supply voltage AC 60 Hz |
0-230 V |
Supply voltage DC |
0-230 V |
Radio standard GPRS |
No |
Radio standard GSM |
No |
Radio standard UMTS |
No |