Register to unlock your exclusive B2B prices and start shopping. Sign up now!
SPD type 2, 3 phase/3 varistors+1 spark-gap/275V Max. (7P.24.8.275.0020) image 1
SPD type 2, 3 phase/3 varistors+1 spark-gap/275V Max. (7P.24.8.275.0020) image 2
SPD type 2, 3 phase/3 varistors+1 spark-gap/275V Max. (7P.24.8.275.0020) image 3
SPD type 2, 3 phase/3 varistors+1 spark-gap/275V Max. (7P.24.8.275.0020) image 4
SPD type 2, 3 phase/3 varistors+1 spark-gap/275V Max. (7P.24.8.275.0020) image 5
SPD type 2, 3 phase/3 varistors+1 spark-gap/275V Max. (7P.24.8.275.0020) thumbnail 1
SPD type 2, 3 phase/3 varistors+1 spark-gap/275V Max. (7P.24.8.275.0020) thumbnail 2
SPD type 2, 3 phase/3 varistors+1 spark-gap/275V Max. (7P.24.8.275.0020) thumbnail 3
SPD type 2, 3 phase/3 varistors+1 spark-gap/275V Max. (7P.24.8.275.0020) thumbnail 4
SPD type 2, 3 phase/3 varistors+1 spark-gap/275V Max. (7P.24.8.275.0020) thumbnail 5

SPD type 2, 3 phase/3 varistors+1 spark-gap/275V Max. (7P.24.8.275.0020)

In stock: No Vendor stock: Yes Minimal order quantity: 1
Price (excl. VAT):
77,783 € per pcs
This price is valid until 31.12.24
EAN: 8012823398143
MPN: 7P2482750020
Package: 1

Technical Information

Item condition New
Manufacture name SPD type 2, 3 phase/3 varistors+1 spark-gap/275V Max. (7P.24.8.275.0020)
Brand FINDER
Categories Lighting protection
Country of origin CZ
Harmonized System Code 8536 3030 00
Mounting method DIN rail (top hat rail) 35 mm
With remote signalling contact No
Number of conductors (without earthing) 4
Construction size 4 modular spacing
Max. continuous voltage AC 275 V
Nominal discharge surge current (8/20) 20 kA
Nominal voltage AC 230 V
Category type 2 Yes
Voltage protection level L-N 1.2 kV
Signalling at the device Optic
Max. continuous voltage DC 350 V
Degree of protection (IP) IP20
Voltage protection level N-PE 1.5 kV
Integrated backup fuse No
System configuration DC No
System configuration IT No
System configuration TN No
System configuration TN-C No
System configuration TN-S Yes
System configuration TT Yes
System configuration other No
System configuration TN-C-S No
Max. discharge surge current (8/20) 40 kA
Short-circuit breaking capacity (Isccr) 50 kA
Max. overcurrent protection device, parallel connection (fuse) 160 A

Packing details

Packing level 1 8012823398143

Downloads

Description

Surge protection device Mounting method: DIN rail (top hat rail) 35 mm With remote signalling contact: no Number of conductors (without earthing): 4 Construction size: 4 modular spacing Max. continuous voltage AC: 275 V. Nominal discharge surge current (8/20): 20 kA. Nominal voltage AC: 230 V. Category type 2: yes Voltage protection level L-N: 1.2 kV. Signalling at the device: Optic Max. continuous voltage DC: 350 V. Protection category: IP20 Voltage protection level N-PE: 1.5 kV. Integrated backup fuse: no System configuration DC: no System configuration IT: no System configuration TN: no System configuration TN-C: no System configuration TN-S: yes System configuration TT: yes System configuration other: no System configuration TN-C-S: no Max. discharge surge current (8/20): 40 kA. Short-circuit breaking capacity (Isccr): 50 kA.