Technical Information

Item condition New
Manufacture name Surge arrester plug-in unit, 280VAC, 10 kA
Brand EATON
Categories Lighting protection
Country of origin RO
Harmonized System Code 8536 5080 00
Mounting method On basic element
With remote signalling contact No
Number of conductors (without earthing) 0
Construction size 1 modular spacing
Voltage protection level 1.2 kV
Max. continuous voltage AC 280 V
Nominal discharge surge current (8/20) 10 kA
Nominal voltage AC 280 V
Nominal voltage DC 0 V
Category type 2 Yes
Voltage protection level L-N 0 kV
Signalling at the device Optic
Max. continuous voltage DC 0 V
Degree of protection (IP) IP20
Max. PV-voltage 0 V
Voltage protection level N-PE 0 kV
Integrated backup fuse No
Max. conductor cross section solid (solid, stranded) 25 mm²
Max. conductor cross section flexible (fine-strand) 0 mm²
System configuration DC No
System configuration IT No
System configuration TN No
System configuration TN-C No
System configuration TN-S No
System configuration TT No
System configuration other Yes
System configuration TN-C-S No
Max. discharge surge current (8/20) 20 kA
Short-circuit breaking capacity (Isccr) 0 kA
Max. overcurrent protection device, parallel connection (fuse) 0 A
Max. overcurrent protection device, series connection (fuse) 100 A
Integrated short-circuit protection No
Integrated short-circuit protection selective to fuse gG 0 A
Leakage-current free No

Packing details

Packing level 1 4015081652303

Description

For protecting consumer systems against transient overvoltages caused by indirect lightning strikes and switching operations, test class II according to IEC 61643-1+A1, SPD-type T2 according to EN 61643-11, can be bussed with all Xtra Combinations switchgear, use in accordance with IEC 60364-5-53 clause 534