Surge arrester plug-in unit, 385VAC, 20 kA

In stock: No Vendor stock: No Minimal order quantity: 2
Price (excl. VAT):
15,50 €
This price is valid until 24.12.24
Subtotal: 31,00 € MOQ: 2
EAN: 4015081640935
MPN: 167602
Package: 1
Box: 2

Technical Information

Item condition New
Manufacture name Surge arrester plug-in unit, 385VAC, 20 kA
Brand EATON
Categories Lighting protection
Country of origin RO
Harmonized System Code 8536 5080 00
Mounting method On basic element
With remote signalling contact No
Number of conductors (without earthing) 0
Construction size 1 modular spacing
Voltage protection level 1.8 kV
Max. continuous voltage AC 385 V
Nominal discharge surge current (8/20) 20 kA
Nominal voltage AC 385 V
Nominal voltage DC 0 V
Category type 2 Yes
Voltage protection level L-N 0 kV
Signalling at the device Optic
Max. continuous voltage DC 0 V
Degree of protection (IP) IP20
Max. PV-voltage 0 V
Voltage protection level N-PE 0 kV
Integrated backup fuse No
Max. conductor cross section solid (solid, stranded) 25 mm²
Max. conductor cross section flexible (fine-strand) 0 mm²
System configuration DC No
System configuration IT No
System configuration TN Yes
System configuration TN-C No
System configuration TN-S No
System configuration TT No
System configuration other Yes
System configuration TN-C-S No
Max. discharge surge current (8/20) 40 kA
Short-circuit breaking capacity (Isccr) 0 kA
Max. overcurrent protection device, parallel connection (fuse) 0 A
Max. overcurrent protection device, series connection (fuse) 125 A
Integrated short-circuit protection No
Integrated short-circuit protection selective to fuse gG 0 A
Leakage-current free No

Packing details

Packing level 1 4015081640935
Packing level 2 9008790474729
Packing level 3 9008790474736

Description

For protecting consumer systems against transient overvoltages caused by indirect lightning strikes and switching operations, test class II according to IEC 61643-1+A1, SPD-type T2 according to EN 61643-11, SPC-S-HK auxiliary contact for remote signaling can be added, can be bussed with all Xtra Combinations switchgear