Register to unlock your exclusive B2B prices and start shopping. Sign up now!
Surge Protective Device, type 1 1 pole, TNS-TNC-TT, 25/50kA, 255V image 1
Surge Protective Device, type 1 1 pole, TNS-TNC-TT, 25/50kA, 255V image 2
Surge Protective Device, type 1 1 pole, TNS-TNC-TT, 25/50kA, 255V thumbnail 1
Surge Protective Device, type 1 1 pole, TNS-TNC-TT, 25/50kA, 255V thumbnail 2

Surge Protective Device, type 1 1 pole, TNS-TNC-TT, 25/50kA, 255V

In stock: No Vendor stock: No Minimal order quantity: 1
Price (excl. VAT):
136,16 €
This price is valid until 24.12.24
EAN: 3660308510877
MPN: 2CTB815101R0100
Package: 1
Box: 5

Technical Information

Item condition New
Manufacture name Surge Protective Device, type 1 1 pole, TNS-TNC-TT, 25/50kA, 255V
Brand ABB
Categories Lighting protection
Country of origin FR
Harmonized System Code 8536 3090 00
Mounting method DIN rail (top hat rail) 35 mm
Lightning impulse current (10/350 µs) 25 kA
With remote signalling contact No
Number of conductors (without earthing) 1
Construction size 2 modular spacing
Voltage protection level 2.5 kV
Suitable for outdoor use No
Exhausting Yes
Follow current extinguishing capability 50 kA
Max. continuous voltage AC 255 V
Nominal discharge surge current (8/20) 25 kA
Nominal voltage AC 230 V
Nominal voltage DC 0 V
Category type 1 Yes
Voltage protection level L-N 2.5 kV
Signalling at the device None
Max. continuous voltage DC 0 V
Degree of protection (IP) IP20
Voltage protection level N-PE 2.5 kV
Integrated backup fuse No
Max. conductor cross section solid (solid, stranded) 50 mm²
Max. conductor cross section flexible (fine-strand) 35 mm²
Voltage protection level (DC+ - DC-) 0 kV
Voltage protection level (DC+/DC- - PE) 0 kV
System configuration DC No
System configuration IT Yes
System configuration TN Yes
System configuration TN-C Yes
System configuration TN-S Yes
System configuration TT Yes
System configuration other No
System configuration TN-C-S Yes

Packing details

Packing level 1 3660308510877
Packing level 2 3660308510877

Description

Blitzstromableiter Typ 1, geprüft nach DIN EN 61643-11, zum Schutz von Niederspannungs-Verbraucheranlagen vor Blitzströmen und Überspannungen. Die Geräte können für den Einsatz als Überspannungs-Schutzeinrichtung nach VDE 0100 Teil 443 und Teil 534, sowie im Rahmen des Blitzschutzzonenkonzeptes verwendet werden. Die Überspannungs-Schutzeinrichtungen bestehen aus nicht ausblasende Funkenstrecke und Doppelklemmen für V-Verdrahtung, optional mit Funktionsanzeige durch LED und potentialfreien Wechselkontakt. Die Überspannungs-Schutzeinrichtungen sind kompatibel mit der Baureihe System pro M compact und mit diesen über Phasenschienen verschienbar und aufrastbar auf Hutschiene 35 mm.