Technical Information
Item condition |
New |
Manufacture name |
swit./blind act. 6-g/3-g 16 A Std OneKNX DRA |
Brand |
Gira
|
Categories |
Sensors
|
Country of origin |
DE |
Harmonized System Code |
8536 4900 00
|
Mounting method |
DRA (DIN-rail adapter) |
Type of current |
DC |
Rated current |
0 A |
Number of inputs |
0 |
Output power |
0 VA |
Rated operating voltage |
NA V |
Bus system KNX |
Yes |
Bus system radio frequent |
No |
Bus system Powernet |
No |
Max. switching power |
0 VA |
With bus connection |
No |
Max. number of switching contacts |
6 |
Max. number of venetian-blind outputs |
3 |
Switching current (resistive) |
0 A |
Width in number of modular spacings |
3 |
Remote operation possible |
No |
Ethernet |
No |
Max. switching current |
16 A |
External signal voltage necessary |
No |
Other bus systems |
None |
Number of switch inputs |
0 |
Number of input channels |
0 |
Number of output channels |
0 |
Bus system LON |
No |
Suitable for C-load |
No |
Input voltage |
NA V |
LED controlling |
No |
Different phases connectable |
No |
Local operation/hand operation |
Yes |
With switch function |
Yes |
Degree of protection (IP) |
IP20 |
With LED indication |
Yes |
Bus system KNX radio |
No |
Packing details
Packing level 1 |
4010337061106 |
Description
Switching actuator, 6-gang 16 A blind actuator, 3-gang 16 A Standard for Gira One und KNX DRA plus Depending on the parameterisation, the actuator can be used as a switching actuator or a blind actuator. Mixed configurations of switching and blind actuators are also possible. For the blind actuator function, two neighbouring relay outputs are combined to form one blind output. Features: Blind or switching operation can be parametrised. In blind operation, the adjacent outputs (A1 A2, A3 A4...) are combined into one blind output. Mixed operation at one actuator (e.g. A1 & A2 blind, A3 & A4 blind, A5 switching, A6 switching ...) is possible. Actively transmitting feedback or status messages can be delayed globally after a bus voltage recovery or ETS programming operation. Manual operation of the outputs independent of KNX with intelligent LED status displays for saving energy. Advanced manual actuation: Toggle between blind mode and switching mode before starting up the ETS. Heartbeat function for monitoring the device, cyclical transmission 1 bit. Bistable relay. Supply from KNX bus, no additional power supply required. Simplified terminal connection (no terminal overlapping). Blind functions: Operating mode can be parametrised: Control of slat blinds, roller shutters, awnings, skylights or ventilation flaps. Separately parameterisable movement times with movement time extension for movements into the upper end position. For slat blinds, a slat movement time can be parametrised independently. Switchover time for change of direction and times for short and long-term operation (Step, Move) can be set. Feedback on the curtain or slat position. In addition, feedback on an invalid curtain position or a drive movement is possible. Assignments of up to 5 different safety functions (3 wind alarms, 1 rain alarm, 1 frost alarm), or with cyclical monitoring. The safety functions (objects, cycle times, priority) are created in a device-based manner for all outputs. An assignment of individual outputs to the safety functions and the safety reactions can be parametrised based on the channel. Blocking function can be implemented for each blind output. Simple sun protection: Sun protection function with fixed and variable curtain or slat positions at the beginning or end of the function can be activated separately for each output. Up to 16 internal scenes can be parametrised per output. Scene memory function: Additional visual feedback. Twilight function. Status messages for upper and lower end positions. Switching functions: Independent switching of the switching outputs. NO contact or NC contact operation. Switching feedback: transmitting to the bus cyclically or when there is a change. Logical individual linking function for each output. Reaction upon bus voltage recovery can be set for each output (ON or no reaction). Blocking function with feedback object can be parametrised for each channel. Time functions (switch-on and switch-off delay, staircase light function – also with advance warning function). Can be integrated in the light scenes: Up to 16 internal scenes can be parametrised per output. Scene memory function: Additional visual feedback. Notes : KNX Data Secure compatible. Fast application download (long frame support). Firmware can be updated using the Gira ETS Service App (additional software). Installation on DIN top-hat rail.