Technical Information
Item condition |
New |
Manufacture name |
Switch actuator REG-K/4x230/16 with manual mode, light grey |
Brand |
Schneider Electric
|
Categories |
Sensors
|
Country of origin |
DE |
Harmonized System Code |
8537 1098 99
|
Mounting method |
DRA (DIN-rail adapter) |
Rated current |
16 A |
Output power |
3600 W |
Rated operating voltage |
230 V |
Bus system KNX |
Yes |
Bus system radio frequent |
No |
Bus system Powernet |
No |
Max. switching power |
3600 W |
With bus connection |
Yes |
Max. number of switching contacts |
4 |
Number of digital inputs |
0 |
Width in number of modular spacings |
4 |
Max. switching current |
16 A |
Bus system LON |
No |
Suitable for C-load |
Yes |
Different phases connectable |
Yes |
Local operation/hand operation |
Yes |
Degree of protection (IP) |
IP20 |
With LED indication |
No |
Modular expandability |
No |
Bus system KNX radio |
No |
Radio frequent bidirectional |
No |
Bus module detachable |
No |
Min. depth of built-in installation box |
0 mm |
Max. switching power LED |
0 W |
Packing details
Packing level 1 |
3606485011783 |
Packing level 2 |
3606485011781 |
Downloads
Description
For independent switching of loads via make contacts. All 230 V switch outputs can be operated with manual switches. With integrated bus coupler. The device is connected to the mains via screw terminals. every second L connection is bridged internally. A green LED indicates readiness for operation after the application has been loaded. For installation on DIN rails TH35 according to EN 60715. The bus is connected using a bus connecting terminal. a data rail is not necessary. KNX software functions:. Operation as break or make contact, delay functions for each channel, staircase lighting function with/without manual OFF function. Cut-out warning for staircase lighting function, blocking and additional logic operation or priority control, scenes, status feedback function per channel, central function. Comprehensive parameterisation for bus voltage failure and recovery, parameterisable download behaviour. Nominal voltage: AC 100-240 V ±10%. Operating voltage: min. AC 90 V - max. AC 265 V. Mains frequency: 50-60 Hz ±10%. For each switching contact: Switching current: 16 A, cos Phi 0.6. AC1 operation: max. 16 A. AC3 operation: max. 10 A. AC5 operation: max. 16 A. DC current switching capacity: max. 16 A/ 24 V DC. Output life endurance: Mechanical: 1000000. AC1/AC3/AC5 operation: 3x10000. 230V, 1A resistive: 8x100000. Nominal load. Incandescent lamps: AC 100 V, max. 1600 W. AC 230 V, max. 3600 W. AC 240 V, max. 3840 W. Halogen lamps: AC 100 V, max. 1086 W. AC 230 V, max. 2500 W. AC 240 V, max. 2608 W. Fluorescent lamps: AC 100 V, max. 1086 VA. AC 230 V, max. 2500 VA. AC 240 V, max. 2608 VA. parallel-compensated. Capacitive load: AC 230 V, 16 A, max. 200 µF. Minimum switching performance: 100 mA/12 V AC/DC. Maximum peak inrush-current: 150µs: 600 A. 250µs: 480 A. 600µs: 300 A. Device width: 4 modules, approx. 72 mm. Contents: With bus connecting terminal and cable cover. Colour: light grey. 4 channel device