Technical Information
Item condition |
New |
Manufacture name |
Digital settable staircase time switch, 1 NO contact 16A |
Brand |
ELTAKO
|
Categories |
Relays
|
Country of origin |
CN |
Harmonized System Code |
8536 5080 00
|
Mounting method |
DIN rail |
Function |
Electronic with multi function |
Built-in depth |
58 mm |
Release-delay |
1 min |
Width in number of modular spacings |
1 |
Control voltage 1 |
230 V |
Control voltage 2 |
8-230 V |
Type of control voltage 1 |
AC |
Type of control voltage 2 |
AC/DC |
Frequency control voltage 1 |
50 Hz |
Wiring system |
3 and 4 wire configuration |
Pre-warning of switching-off |
Flickering |
Repetitive |
Repetitive + continuous light + time extension |
Voltage type of supply voltage |
AC |
Supply voltage |
250 V |
Max. switching current (cos phi = 0.6) |
4 A |
Max. incandescent lamp load |
2300 W |
Max. load fluorescent lamp |
1000 VA |
Max. load fluorescent lamp (Duo circuit) |
1000 VA |
Max. load fluorescent lamp (parallel compensated) |
500 VA |
Rated switch current |
16 A |
Push button glow-lamp current |
50 mA |
Current surge function selectable |
Yes |
Number of contacts as normally closed contact |
0 |
Number of contacts as normally open contact |
1 |
Number of contacts as change-over contact |
0 |
Max. switching power LED |
200 W |
Packing details
Packing level 1 |
4010312401712, 4010312401712 |
Packing level 2 |
4010312401712 |
Packing level 3 |
4010312401712 |
Downloads
Description
1 NO contact not potential free 16A/250V AC. 230V LED lamps up to 600W, energy saving lamps ESL up to 200W, incandescent lamps up to 2300W. Control voltage 230V and/or 8..230V UC. Switch-off early warning and permanent light by pushbutton switchable. Standby loss 0.5 watt only. With ESL optimisation and multifunction. Modular device for DIN EN 60715 TH35 rail mounting. 1 module = 18mm wide, 58mm deep. The functions and times are entered using the MODE and SET keys as described in the operating manual and indicated on the LC display. A keylock function is provided. Zero passage switching to protect contacts and lamps. The noiseless electronics do not even bother the sensitive ear – unlike many synchronous motors with mechanical gears. By using a bistable relay coil power loss and heating is avoided even in the on mode. The switched consumer may not be connected to the mains before the short automatic synchronisation after installation has terminated. Control voltage, supply voltage and switching voltage 230V. In addition electrically isolated universal voltage from 8 to 230V UC. 3-wire and 4-wire circuits, resettable, with attic lighting if 4-wire circuit. Automatic detection of the method of connection. Glow lamp current up to 50mA, dependent on the ignition voltage of the glow lamps. Precise variable time range from 1 to 99 minutes. Separate continuous light pushbutton with projecting SET button in the functions STS, ISO, IS and R. With motion detector control input BM, which converts the input signal into a control impulse if the function STS is set. In this case the permanent light by pushbutton function is not active. If the function STS is set, the lighting is switched on again after a power failure provided the set time has not yet elapsed. The elapsed period is shown in the middle of the display. The set time flashes at the bottom edge of the display until the set period elapses. The accrued switch-on time is displayed there outside the elapsed time, first in hours (h), then in months (m) with 1 digit after the decimal point. When the set time flashes but the elapsed time does not change, a control pushbutton is inhibited. If switch-off early warning function is switched on, the light starts flickering in time variable from 10 to 50 seconds before time-out and is repeated three times at decreasing time intervals. If permanent light by pushbutton is switched on, permanent light can be switched on by pressing the pushbutton longer than 1 second. This is switched off automatically after time variable from 0.5 to 10 hours or by pressing the pushbutton longer than 2 seconds. This function is not active at the BM input. If both switch-off early warning function and permanent light by pushbutton are switched on, the switch-off early warning function is activated before the permanent light switches off. If energy saving lamps are switched completely or partially, activate position ESL in the menu guidance. This is indicated by a + sign next to the abbreviation for the function at the top of the display. If the function STS is selected the time can be extended within the first second after switching on or resetting by pressing the pushbutton repeatedly up to three times (incrementing). Each momentary-contact control increments the set time once. This function is not active at the BM input. With multifunction: Switchable to the functions IS (impulse switch), R (relay), ISO (impulse switch with off-delay) and HC (hour counter). After setting the required function, the function can be blocked. An arrow on the right of the abbreviation indicates the blocking status. ISO: The impulse switch automatically disconnects after the set delay from 0.1 to 9.9 hours is timed out, provided there is no manual OFF command. Switch-off early warning, permanent light by pushbutton and ESL are also switchable if the function ISO is set. HC: As long as the pushbutton input is excited, the + sign is indicated next to the abbreviation for the function HC at the top of the display. The time is added and indicated at the bottom of the display. Initially up to 9999 hours (h), then automatic change-over to months (m) each with 730 hours and display with 1 digit after the decimal point. The relay is not switched on if the funtion HC is set. Menu guidance with selectable languages German, English or French as described in the attached operating instructions.