Register to unlock your exclusive B2B prices and start shopping. Sign up now!
Transformer-protective circuit-breaker, 3p, Ir=1.6-2.5A, screw connection image 1
Transformer-protective circuit-breaker, 3p, Ir=1.6-2.5A, screw connection image 2
Transformer-protective circuit-breaker, 3p, Ir=1.6-2.5A, screw connection image 3
Transformer-protective circuit-breaker, 3p, Ir=1.6-2.5A, screw connection image 4
Transformer-protective circuit-breaker, 3p, Ir=1.6-2.5A, screw connection image 5
Transformer-protective circuit-breaker, 3p, Ir=1.6-2.5A, screw connection image 6
Transformer-protective circuit-breaker, 3p, Ir=1.6-2.5A, screw connection image 7
Transformer-protective circuit-breaker, 3p, Ir=1.6-2.5A, screw connection image 8
Transformer-protective circuit-breaker, 3p, Ir=1.6-2.5A, screw connection image 9
Transformer-protective circuit-breaker, 3p, Ir=1.6-2.5A, screw connection image 10
Transformer-protective circuit-breaker, 3p, Ir=1.6-2.5A, screw connection image 11
Transformer-protective circuit-breaker, 3p, Ir=1.6-2.5A, screw connection image 12
Transformer-protective circuit-breaker, 3p, Ir=1.6-2.5A, screw connection image 13
Transformer-protective circuit-breaker, 3p, Ir=1.6-2.5A, screw connection image 14
Transformer-protective circuit-breaker, 3p, Ir=1.6-2.5A, screw connection image 15
Transformer-protective circuit-breaker, 3p, Ir=1.6-2.5A, screw connection image 16
Transformer-protective circuit-breaker, 3p, Ir=1.6-2.5A, screw connection image 17
Transformer-protective circuit-breaker, 3p, Ir=1.6-2.5A, screw connection thumbnail 1
Transformer-protective circuit-breaker, 3p, Ir=1.6-2.5A, screw connection thumbnail 2
Transformer-protective circuit-breaker, 3p, Ir=1.6-2.5A, screw connection thumbnail 3
Transformer-protective circuit-breaker, 3p, Ir=1.6-2.5A, screw connection thumbnail 4
Transformer-protective circuit-breaker, 3p, Ir=1.6-2.5A, screw connection thumbnail 5
Transformer-protective circuit-breaker, 3p, Ir=1.6-2.5A, screw connection thumbnail 6
Transformer-protective circuit-breaker, 3p, Ir=1.6-2.5A, screw connection thumbnail 7
Transformer-protective circuit-breaker, 3p, Ir=1.6-2.5A, screw connection thumbnail 8
Transformer-protective circuit-breaker, 3p, Ir=1.6-2.5A, screw connection thumbnail 9
Transformer-protective circuit-breaker, 3p, Ir=1.6-2.5A, screw connection thumbnail 10
Transformer-protective circuit-breaker, 3p, Ir=1.6-2.5A, screw connection thumbnail 11
Transformer-protective circuit-breaker, 3p, Ir=1.6-2.5A, screw connection thumbnail 12
Transformer-protective circuit-breaker, 3p, Ir=1.6-2.5A, screw connection thumbnail 13
Transformer-protective circuit-breaker, 3p, Ir=1.6-2.5A, screw connection thumbnail 14
Transformer-protective circuit-breaker, 3p, Ir=1.6-2.5A, screw connection thumbnail 15
Transformer-protective circuit-breaker, 3p, Ir=1.6-2.5A, screw connection thumbnail 16
Transformer-protective circuit-breaker, 3p, Ir=1.6-2.5A, screw connection thumbnail 17

Transformer-protective circuit-breaker, 3p, Ir=1.6-2.5A, screw connection

In stock: No Vendor stock: No Minimal order quantity: 1
Price (excl. VAT):
33,67 €
This price is valid until 31.12.24
EAN: 4015080889137
MPN: 088913
Package: 1

Technical Information

Item condition New
Manufacture name Transformer-protective circuit-breaker, 3p, Ir=1.6-2.5A, screw connection
Brand EATON
Categories Breakers
Country of origin DE
Harmonized System Code 8536 2010 00
Number of auxiliary contacts as normally open contact 0
Number of auxiliary contacts as normally closed contact 0
Rated permanent current Iu 2.5 A
With integrated under voltage release No
Number of poles 3
Overload release current setting 1.6-2.5 A
Number of auxiliary contacts as change-over contact 0
Rated voltage 690 V
Degree of protection (IP) IP20
Position of connection for main current circuit Other
Motor drive integrated No
Type of electrical connection of main circuit Screw connection
Type of control element Turn button
With switched-off indicator Yes
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz 150 kA
Adjustment range short-term delayed short-circuit release 0 A
Adjustment range undelayed short-circuit release 50 A
Suitable for DIN rail (top hat rail) mounting Yes
Integrated earth fault protection No
Motor drive optional No
Device construction Built-in device fixed built-in technique
DIN rail (top hat rail) mounting optional Yes
Complete device with protection unit Yes

Packing details

Packing level 1 4015080889137

Description

Transformer circuit-breaker according to IEC/EN60947, 3 pole size PKZM0, with adjustable overload and non-delayed short-circuit release, phase failure sensitive, screw and snap fitting, with screw terminal, cap installation dimension 45mm, rated operating voltage Ue 690V, degree of protection IP20, finger proof according to VDE 0106 T. 100, accessories: auxiliary contact, voltage release

Similar items

Accessories

Similar items

Suitable for

Similar items
4015081013715 4015081013722 4015081014019 4015081059027 4015081059034 4015082196547 4015082196554 4015082322892 4015082322908 4015082625184
Accessories
4015081013715 4015081013722 4015081014019 4015081059027 4015081059034 4015082196547 4015082196554 4015082322892 4015082322908 4015082625184
Similar items
4015082322892 4015080828815 4015080639602 4015080731351 4015080327202 4015080731382 4015080728948 4015080828822 4015080728962 4015080639619
Suitable for
4015080327202 4015080639619 4015080639602 4015080728948 4015080728962 4015080731351 4015080731382 4015080828815 4015080828822 4015080828846