Application in domestic- and commercial area permitted
Yes
Max. output frequency
400 Hz
Max. output at linear load at rated output voltage
45 kW
Max. output at quadratic load at rated output voltage
55 kW
Relative symmetric net voltage tolerance
10 %
Relative symmetric net frequency tolerance
10 %
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for EtherNet/IP
Yes
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for PROFINET IO
Yes
Supporting protocol for PROFIsafe
No
Supporting protocol for SafetyBUS p
No
Max. output voltage
500 V
Nominal output current I2N
87 A
Supporting protocol for BACnet
Yes
Degree of protection (NEMA)
12
Packing details
Packing level 1
4015081710980
Description
Variable frequency drive, Part group reference (e.g. DIL): DG1, Rated operational voltage: Ue = 400 V AC, 3-phase, 480 V AC, 3-phase, 500 V AC, 3-phase, Output voltage with Ve: U2 = 400 V AC, 3-phase, 480 V AC, 3-phase, 500 V AC, 3-phase, Mains voltage (50/60Hz): ULN = 380 (-15%) - 500 (+10%) V, Rated operational current At 150% overload: Ie = 87 A, Note: Rated operational current for a switching frequency of 1 - 10 kHz and an ambient temperature of +50 °C for a 150% overload and +40 °C for a 110% overload, Rated operational current At 110% overload: Ie = 105 A, Note: Overload cycle for 60 s every 600 s , Assigned motor rating Note: for normal internally and externally ventilated 4 pole, three-phase asynchronous motors with 1500 rpm-1 at 50 Hz or 1800 min-1 at 60 Hz, Overload cycle for 60 s every 600 s, at 400 V, 50 Hz, Assigned motor rating 150 % Overload: P = 45 kW, 110 % Overload: P = 55 kW, 150 % Overload: IM = 82.1 A, 110 % Overload: IM = 99 A, Assigned motor rating Note: at 500 V, 50 Hz, Assigned motor rating 150 % Overload: P = 55 kW, 110 % Overload: P = 55 kW, 150 % Overload: IM = 79 A, 110 % Overload: IM = 79 A, Assigned motor rating Note: at 480 V, 60 Hz, Assigned motor rating 150 % Overload: P = 60 HP, 110 % Overload: P = 75 HP , Assigned motor rating 150 % Overload: IM = 77 A, 110 % Overload: IM = 96 A, Degree of Protection: IP54/NEMA12, Interface/field bus (built-in): Modbus RTU, Modbus TCP, BACnet MS/TP, Ethernet IP, Fieldbus connection (optional): PROFIBUS, CANopen®, DeviceNet, SmartWire-DT, Fitted with: Radio interference suppression filter, Additional PCB protection, Multi-line graphic display, DC link choke, Frame size: FS4, Standards: Specification for general requirements: IEC/EN 61800-2, EMC requirements: IEC/EN 61800-3, Safety requirements: IEC/EN 61800-5