Contactor, 3 pole, 380 V 400 V 18.5 kW, 230 V 50 Hz, 240 V 60 Hz, AC operation, Spring-loaded terminals image 1
Contactor, 3 pole, 380 V 400 V 18.5 kW, 230 V 50 Hz, 240 V 60 Hz, AC operation, Spring-loaded terminals image 2
Contactor, 3 pole, 380 V 400 V 18.5 kW, 230 V 50 Hz, 240 V 60 Hz, AC operation, Spring-loaded terminals thumbnail 1
Contactor, 3 pole, 380 V 400 V 18.5 kW, 230 V 50 Hz, 240 V 60 Hz, AC operation, Spring-loaded terminals thumbnail 2

Contactor, 3 pole, 380 V 400 V 18.5 kW, 230 V 50 Hz, 240 V 60 Hz, AC operation, Spring-loaded terminals

In stock: No Vendor stock: No Minimal order quantity: 1
Price (excl. VAT):
82,50 €
This price is valid until 24.12.24
EAN: 4015081879434
MPN: 189947
Package: 1

Technical Information

Item condition New
Manufacture name Contactor, 3 pole, 380 V 400 V 18.5 kW, 230 V 50 Hz, 240 V 60 Hz, AC operation, Spring-loaded terminals
Brand EATON
Categories Modular switches
Country of origin RO
Harmonized System Code 8536 4900 00
Modular version No
Rated operation power at AC-3, 400 V 18.5 kW
Number of normally open contacts as main contact 3
Number of normally closed contacts as main contact 0
Number of auxiliary contacts as normally open contact 0
Number of auxiliary contacts as normally closed contact 0
Rated operation current Ie at AC-3, 400 V 40 A
Rated operation current Ie at AC-1, 400 V 60 A
Rated control supply voltage at AC 50 Hz 230 V
Rated control supply voltage at AC 60 Hz 240 V
Rated control supply voltage at DC 0 V
Type of electrical connection of main circuit Spring clamp connection
Voltage type for actuating AC
Rated operation current Ie at AC-4, 400 V 18 A
Rated operation power at AC-4, 400 V 9 kW
Rated operation power NEMA 22 kW

Packing details

Packing level 1 4015081879434

Description

Contactor, Application: Contactors for Motors, Contactors up to 170 A, 3 pole, Utilization category: AC-1: Non-inductive or slightly inductive loads, resistance furnaces, NAC-3: Normal AC induction motors: starting, switch off during running, AC-4: Normal AC induction motors: starting, plugging, reversing, inching, Connection technique: Spring-loaded terminals, Notes: Also suitable for motors with efficiency class IE3., IE3-ready devices are identified by the logo on their packaging., Description: Spring-cage terminals on auxiliary and control circuit terminals, Number of poles: 3 pole, Rated operational current AC-3 380 V 400 V: Ie= 40 A , Rated operational current AC-1 Conventional free air thermal current, 3 pole, 50 - 60 Hz Open at 40 °C: Ith =Ie= 60 A, enclosed: Ith= 45 A, Rated operational current AC-1 Conventional free air thermal current, 1 pole open: Ith= 125 A, enclosed: Ith= 112 A, Max. rating for three-phase motors, 50 - 60 Hz AC-3 220 V 230 V: P= 12.5 kW, 380 V 400 V: P= 18.5 kW, 660 V 690 V: P= 23 kW, Max. rating for three-phase motors, 50 - 60 Hz AC-4 220 V 230 V: P= 5 kW, 380 V 400 V: P= 9 kW, 660 V 690 V: P= 12 kW, Can be combined with auxiliary contact: DILM150-XHIC(V)…, DILM1000-XHIC…, Instructions: Contacts to EN 50 012., Auxiliary current, coil , and main current terminals with spring-cage connection technology., Main current connections with screw terminals., Voltage AC/DC: AC operation