Technical Information
Item condition |
New |
Manufacture name |
Weather station REG-K/4-gang, light grey |
Brand |
Schneider Electric
|
Categories |
Sensors
|
Country of origin |
DE |
Mounting method |
DRA (DIN-rail adapter) |
Colour |
Grey |
Bus system KNX |
Yes |
Bus system radio frequent |
No |
Bus system Powernet |
No |
With bus connection |
Yes |
With heating |
No |
Number of digital inputs |
0 |
Analogue input |
Yes |
Other bus systems |
None |
Bus system LON |
No |
RAL-number (similar) |
7035 |
Weather station |
Yes |
Degree of protection (IP) |
IP20 |
With DCF77 |
Yes |
Acoustic signal |
No |
Bus system KNX radio |
No |
Radio frequent bidirectional |
No |
Packing details
Packing level 1 |
3606485012346 |
Packing level 2 |
3606485012344 |
Downloads
Description
The weather station records and processes analogue sensor signals such as wind speed, brightness, twilight, precipitation and a DCF-77 signal. Up to four analogue sensors and the DCF-77 weather combi-sensor can be connected in any combination. If DCF-77 weather combi-sensors are used, it is possible to access a pre-configured setting in the software. The measured values are converted by the weather station into 1 byte / 2 byte telegrams (EIS 6/5 value). This enables bus devices (visualisation software, measured value displays) to access the control processes, generate signals or control weather-dependent processes. Programming is performed using the ETS tool for the weather station. Functions:-Two limit values per sensor (not for rain). Connection of multiple wind sensors. 14 signals can be evaluated. Evaluation of DCF-77 time signal (date and time). Astro function. Logic operation controller for application of limit-value-dependent actions (even external). Shading of individual façade segments. Signal monitoring of the combi-sensors with object for the following protective measures. Checking the wind signal for conclusiveness with object for the following protective measures. Selective façade shading (for 4 façades) with adjustment of the basic brightness, façade alignment, angle of opening relative to the sun. External objects for intervention in basic brightness, angle of opening and limit values: -Alarm byte. -Continuity monitoring with report on the bus. For installation on DIN rails TH35 according to EN 60715. The bus is connected using a bus connecting terminal. a data rail is not necessary. Auxiliary voltage: AC 24 V (+/-10 %). Analogue inputs: 4. Current interface: 0-20 mA, 4-20 mA. Voltage interface: 0-1 V, 0-10 V. utputs: DC 24 V, 100 mA. Device width: 4 modules, approx. 72 mm. Contents: With bus connecting terminal and cable cover. Colour: light grey.