Item condition |
New |
Manufacture name |
ACS355-03E-07A3-4 Pn 3,0kW, I2n 7,3A IP20. |
Brand |
ABB
|
Categories |
Control gear
|
Country of origin |
CN |
Width |
70 mm |
Height |
239 mm |
Depth |
161 mm |
With control element |
Yes |
Number of digital inputs |
5 |
Number of digital outputs |
1 |
Number of analogue inputs |
2 |
Number of analogue outputs |
1 |
Supporting protocol for LON |
Yes |
Number of HW-interfaces industrial Ethernet |
0 |
Number of HW-interfaces RS-232 |
1 |
Number of HW-interfaces RS-422 |
0 |
Number of HW-interfaces RS-485 |
1 |
Number of HW-interfaces serial TTY |
0 |
Number of HW-interfaces USB |
0 |
Number of HW-interfaces parallel |
0 |
Number of HW-interfaces other |
1 |
With optical interface |
Yes |
Supporting protocol for TCP/IP |
Yes |
Supporting protocol for ASI |
Yes |
Supporting protocol for PROFIBUS |
Yes |
Supporting protocol for CAN |
Yes |
Supporting protocol for INTERBUS |
Yes |
Supporting protocol for KNX |
Yes |
Supporting protocol for Modbus |
Yes |
Supporting protocol for Data-Highway |
Yes |
Supporting protocol for DeviceNet |
Yes |
Supporting protocol for SUCONET |
Yes |
Supporting protocol for other bus systems |
Yes |
Degree of protection (IP) |
IP20 |
With PC connection |
Yes |
Supporting protocol for SERCOS |
Yes |
Supporting protocol for INTERBUS-Safety |
Yes |
Mains voltage |
380-480 V |
Mains frequency |
50/60 Hz |
4-quadrant operation possible |
Yes |
Number of interfaces PROFINET |
0 |
Type of converter |
U converter |
Number of phases output |
3 |
Number of phases input |
3 |
Integrated breaking resistance |
Yes |
Application in industrial area permitted |
Yes |
Application in domestic- and commercial area permitted |
Yes |
Max. output frequency |
599 Hz |
Max. output at linear load at rated output voltage |
3 kW |
Max. output at quadratic load at rated output voltage |
3 kW |
Relative symmetric net voltage tolerance |
10 % |
Relative symmetric net frequency tolerance |
5 % |
Supporting protocol for AS-Interface Safety at Work |
Yes |
Supporting protocol for DeviceNet Safety |
Yes |
Supporting protocol for EtherNet/IP |
Yes |
Supporting protocol for Foundation Fieldbus |
Yes |
Supporting protocol for PROFINET CBA |
Yes |
Supporting protocol for PROFINET IO |
Yes |
Supporting protocol for PROFIsafe |
Yes |
Supporting protocol for SafetyBUS p |
Yes |
Max. output voltage |
480 V |
Nominal output current I2N |
7.3 A |
Supporting protocol for BACnet |
Yes |
Degree of protection (NEMA) |
Other |