Item condition |
New |
Manufacture name |
Temperature module |
Brand |
Phoenix Contact
|
Categories |
Programmable logic controllers
|
Country of origin |
DE |
Harmonized System Code |
8538 9099 00
|
Width |
12.15 mm |
Height |
138.44 mm |
Depth |
70.51 mm |
Suitable for safety functions |
No |
Number of analogue inputs |
0 |
Number of analogue outputs |
0 |
Voltage type of supply voltage |
DC |
Supporting protocol for LON |
No |
Number of HW-interfaces industrial Ethernet |
0 |
Number of HW-interfaces RS-232 |
0 |
Number of HW-interfaces RS-422 |
0 |
Number of HW-interfaces RS-485 |
0 |
Number of HW-interfaces serial TTY |
0 |
Number of HW-interfaces USB |
0 |
Number of HW-interfaces parallel |
0 |
Number of HW-interfaces other |
2 |
Supporting protocol for TCP/IP |
No |
Supporting protocol for ASI |
No |
Supporting protocol for PROFIBUS |
No |
Supporting protocol for CAN |
No |
Supporting protocol for INTERBUS |
No |
Supporting protocol for KNX |
No |
Supporting protocol for Modbus |
No |
Supporting protocol for Data-Highway |
No |
Supporting protocol for DeviceNet |
No |
Supporting protocol for SUCONET |
No |
Supporting protocol for other bus systems |
Yes |
Input, current |
No |
Input, voltage |
No |
Input, resistor |
Yes |
Input, resistance thermometer |
Yes |
Input, thermocouple |
No |
Input signal, configurable |
No |
Output, current |
No |
Output, voltage |
No |
Output signal configurable |
No |
Resolution of the analogue inputs |
16 Bit |
Resolution of the analogue outputs |
0 Bit |
Type of electric connection |
Other |
Rail mounting possible |
Yes |
Fieldbus connection over separate bus coupler possible |
Yes |
System accessory |
Yes |
Appendant operation agent (Ex ia) |
No |
Appendant operation agent (Ex ib) |
No |
Degree of protection (IP) |
IP20 |
Supporting protocol for SERCOS |
No |
Supporting protocol for INTERBUS-Safety |
No |
Number of interfaces PROFINET |
0 |
Number of HW-interfaces Wireless |
0 |
Front built-in possible |
No |
Rack-assembly possible |
No |
Wall mounting/direct mounting |
No |
IO link master |
No |
Supporting protocol for AS-Interface Safety at Work |
No |
Supporting protocol for DeviceNet Safety |
No |
Supporting protocol for EtherNet/IP |
No |
Supporting protocol for Foundation Fieldbus |
No |
Supporting protocol for PROFINET CBA |
No |
Supporting protocol for PROFINET IO |
No |
Supporting protocol for PROFIsafe |
No |
Supporting protocol for SafetyBUS p |
No |
Supply voltage AC 50 Hz |
0 V |
Supply voltage AC 60 Hz |
0 V |
Supply voltage DC |
19.2-30 V |
Analogue inputs configurable |
No |
Analogue outputs configurable |
No |
SIL according to IEC 61508 |
None |