Register to unlock your exclusive B2B prices and start shopping. Sign up now!
Cable category 6 F/UTP 2x4 pairs LSZH 500 meters image 1
Cable category 6 F/UTP 2x4 pairs LSZH 500 meters image 2
Cable category 6 F/UTP 2x4 pairs LSZH 500 meters thumbnail 1
Cable category 6 F/UTP 2x4 pairs LSZH 500 meters thumbnail 2

Cable category 6 F/UTP 2x4 pairs LSZH 500 meters

In stock: No Vendor stock: No Minimal order quantity: 500
Price (excl. VAT):
2,12 € per m
This price is valid until 31.01.25
Subtotal: 1 060,00 € MOQ: 500
EAN: 3245060327767
MPN: 032776
Package: 1
Box: 500
Pallet: 3000

Technical Information

Item condition New
Manufacture name Cable category 6 F/UTP 2x4 pairs LSZH 500 meters
Brand Legrand
Categories Ethernet cable (network)
Country of origin CN
Harmonized System Code 8544 4920 00
UV resistant No
Nominal cross section conductor 0.25 mm²
Material core insulation Other
Core identification Colour
Weight 0 kg/km
Flame retardant According to IEC/EN 60332-1-2
Circuit integrity None
Stranding element Pairs
Colour outer sheath Blue
Category 6
Diameter conductor 0.56 mm
Conductor material Copper
Screen over stranding element None
Screen over stranding Foil
Material outer sheath Other
Conductor category Class 1 = solid
Armouring/reinforcement None
Permitted cable outer temperature during assembling/handling 0-50 °C
Permitted cable outer temperature after assembling without vibration -20-60 °C
Number of stranding elements 8
Protective sheath None
Number of cores 16
Suitable for underground installation No
Halogen free according to IEC 60754-2 Yes
Insulation integrity according to IEC 60331 No
Low smoke according to IEC 61034-2 Yes
Stranding Bundle
Outer diameter approx. 7.3 mm
Low smoke (according to EN 61034-2) Yes
NVP value 66 %
Halogen free according to EN 60754-1/2 Yes
Conductor surface Bare
Longitudinal water blocking cable No
Radial water blocking cable Yes
Reaction-to-fire according to EN 13501-6: Class Dca
Reaction-to-fire according to EN 13501-6: Smoke production s2
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles d2
Reaction-to-fire according to EN 13501-6: Acidity a1
AWG size 23
Min. permitted bending radius, moving application with forced guidance 59 mm
Min. permitted bending radius, moving application/free movement 0 mm
Min. permitted bending radius, stationary application/permanent installation 29.5 mm
Specification core insulation Polyethylene (PE)
Specification material outer sheath Other
Cable geometry Other
Suitable as telephone cable Yes
Suitable as computer data cable Yes
Suitable as signalling cable Yes
Approved type of underground installation Other
Compatible with Grade2TV according to XP-C 90-483 No
Compatible with Grade3TV according to XP-C 90-483 No

Packing details

Packing level 1 3245060327767
Packing level 2 3414971346963
Packing level 3 3245060327767