Register to unlock your exclusive B2B prices. Register now
Contactor, 220 V DC, 3 pole, 380 V 400 V, 4 kW, Contacts N/O = Normally open= 1 N/O, Screw terminals, DC operation image 1
Contactor, 220 V DC, 3 pole, 380 V 400 V, 4 kW, Contacts N/O = Normally open= 1 N/O, Screw terminals, DC operation image 2
Contactor, 220 V DC, 3 pole, 380 V 400 V, 4 kW, Contacts N/O = Normally open= 1 N/O, Screw terminals, DC operation image 3
Contactor, 220 V DC, 3 pole, 380 V 400 V, 4 kW, Contacts N/O = Normally open= 1 N/O, Screw terminals, DC operation image 4
Contactor, 220 V DC, 3 pole, 380 V 400 V, 4 kW, Contacts N/O = Normally open= 1 N/O, Screw terminals, DC operation image 5
Contactor, 220 V DC, 3 pole, 380 V 400 V, 4 kW, Contacts N/O = Normally open= 1 N/O, Screw terminals, DC operation image 6
Contactor, 220 V DC, 3 pole, 380 V 400 V, 4 kW, Contacts N/O = Normally open= 1 N/O, Screw terminals, DC operation image 7
Contactor, 220 V DC, 3 pole, 380 V 400 V, 4 kW, Contacts N/O = Normally open= 1 N/O, Screw terminals, DC operation image 8
Contactor, 220 V DC, 3 pole, 380 V 400 V, 4 kW, Contacts N/O = Normally open= 1 N/O, Screw terminals, DC operation image 9
Contactor, 220 V DC, 3 pole, 380 V 400 V, 4 kW, Contacts N/O = Normally open= 1 N/O, Screw terminals, DC operation image 10
Contactor, 220 V DC, 3 pole, 380 V 400 V, 4 kW, Contacts N/O = Normally open= 1 N/O, Screw terminals, DC operation image 11
Contactor, 220 V DC, 3 pole, 380 V 400 V, 4 kW, Contacts N/O = Normally open= 1 N/O, Screw terminals, DC operation image 12
Contactor, 220 V DC, 3 pole, 380 V 400 V, 4 kW, Contacts N/O = Normally open= 1 N/O, Screw terminals, DC operation image 13
Contactor, 220 V DC, 3 pole, 380 V 400 V, 4 kW, Contacts N/O = Normally open= 1 N/O, Screw terminals, DC operation image 14
Contactor, 220 V DC, 3 pole, 380 V 400 V, 4 kW, Contacts N/O = Normally open= 1 N/O, Screw terminals, DC operation image 15
Contactor, 220 V DC, 3 pole, 380 V 400 V, 4 kW, Contacts N/O = Normally open= 1 N/O, Screw terminals, DC operation image 16
Contactor, 220 V DC, 3 pole, 380 V 400 V, 4 kW, Contacts N/O = Normally open= 1 N/O, Screw terminals, DC operation image 17
Contactor, 220 V DC, 3 pole, 380 V 400 V, 4 kW, Contacts N/O = Normally open= 1 N/O, Screw terminals, DC operation image 18
Contactor, 220 V DC, 3 pole, 380 V 400 V, 4 kW, Contacts N/O = Normally open= 1 N/O, Screw terminals, DC operation image 19
Contactor, 220 V DC, 3 pole, 380 V 400 V, 4 kW, Contacts N/O = Normally open= 1 N/O, Screw terminals, DC operation image 20

Contactor, 220 V DC, 3 pole, 380 V 400 V, 4 kW, Contacts N/O = Normally open= 1 N/O, Screw terminals, DC operation

In stock price (excl. VAT):
24,05 €
This price is valid until 2024-12-31
Price per m: 24,05 €
EAN: 4015080103257
MPN: 010325
Our warehouse: No Vendor stock: No
Per package: 1 Per box: 5 Per pallet: N/A
Technical data
Item condition New
Brand EATON
Categories Modular switches
Country of origin DE
Harmonized System Code 8536 4900 00
Modular version No
Rated operation power at AC-3, 400 V 4.000 kW
Number of normally open contacts as main contact 3.000
Number of normally closed contacts as main contact 0.000
Number of auxiliary contacts as normally open contact 1.000
Number of auxiliary contacts as normally closed contact 0.000
Rated operation current Ie at AC-3, 400 V 9.000 A
Rated operation current Ie at AC-1, 400 V 22.000 A
Rated control supply voltage at AC 50 Hz 0.000 V
Rated control supply voltage at AC 60 Hz 0.000 V
Rated control supply voltage at DC 220.000 V
Type of electrical connection of main circuit Screw connection
Voltage type for actuating DC
Rated operation current Ie at AC-4, 400 V 6.600 A
Rated operation power at AC-4, 400 V 3.000 kW
Rated operation power NEMA 3.700 kW
Packing details
Packing level 1 4015080103257
Packing level 2 4015081834433
Downloads
Description
Contactor, Application: Mini Contactors for Motors and Resistive Loads, DILEM contactors, Utilization category: AC-1: Non-inductive or slightly inductive loads, resistance furnaces, NAC-3: Normal AC induction motors: starting, switch off during running, AC-4: Normal AC induction motors: starting, plugging, reversing, inching, Connection technique: Screw terminals, Notes: Also suitable for motors with efficiency class IE3., IE3-ready devices are identified by the logo on their packaging., Description: With auxiliary contact, Number of poles: 3 pole, Rated operational current AC-3 380 V 400 V: Ie= 9 A , Rated operational current AC-1 Conventional free air thermal current, 3 pole, 50 - 60 Hz Open at 40 °C: Ith =Ie= 22 A, enclosed: Ith= 16 A, Rated operational current AC-1 Conventional free air thermal current, 1 pole open: Ith= 50 A, enclosed: Ith= 40 A, Max. rating for three-phase motors, 50 - 60 Hz AC-3 220 V 230 V: P= 2.2 kW, 380 V 400 V: P= 4 kW, 660 V 690 V: P= 4 kW, Max. rating for three-phase motors, 50 - 60 Hz AC-4 220 V 230 V: P= 1.5 kW, 380 V 400 V: P= 3 kW, 660 V 690 V: P= 3 kW, For use with: …DILEM, …DILE, Contacts N/O = Normally open: 1 N/O, Voltage AC/DC: DC operation

Similar items

Accessories

Similar items

Suitable for

Similar items
8021696014432 4015080143338 4015080143765 4015080144793 4015080145189 4015080145653 4015080147084 4015080489122 4015080498230 4015080830948 4015082202095
Accessories
8021696014432 4015080143338 4015080143765 4015080144793 4015080145189 4015080145653 4015080147084 4015080489122 4015080498230 4015080830948 4015082202095
Similar items
4015080102885 4015080102243 4015080102564 4015080103042 4015080145189 4015080100805 4015080489122 4015080023975 4015080498230 4015080143000
Suitable for
4015080830948 4015082202095 4015080023975 4015080100805 4015080101123 4015080101130 4015080102243 4015080102885 4015080102564 4015080103042