Technical Information
Item condition |
New |
Manufacture name |
ctrl.unit 1 - 10 V 4-g man.act. KNX |
Brand |
Gira
|
Categories |
Sensors
|
Country of origin |
DE |
Harmonized System Code |
8542 3190 00
|
Mounting method |
DRA (DIN-rail adapter) |
Number of outputs |
0 |
Bus system KNX |
Yes |
Bus system radio frequent |
No |
Bus system Powernet |
No |
With bus connection |
No |
Width in number of modular spacings |
4 |
Bus system LON |
No |
Local operation/hand operation |
Yes |
Degree of protection (IP) |
IP20 |
Bus system KNX radio |
No |
Packing details
Packing level 1 |
4010337018858 |
Description
Control unit 1 - 10 V, 4-gang with manual actuation for KNX DRA plus Features: The controller unit switches and dims electrical devices that have a 1-10 V interface. Five device configurations can be selected. This leads to the assignment of four individually-controllable dimming channels to the switching outputs (e.g. four dimming channels are assigned to one switching relay to control a RGBW light). Relay outputs that are not associated with a dimming channel can be used as freely-acting switching actuator channel. Reactions in case of bus voltage failure and restoration can be set following an ETS programming process. Manual actution of outputs independent of the bus with mechanical switching position indication. Delay for actively transmitted feedback messages following bus voltage recovery. Logical linking function configurable per channel. Up to three central switching functions for the joint control of all dimming and switching channels. Switch-on times of the relay outputs can be recorded and evaluated by the elapsedoperating time meter. Group feedback of all switching conditions possible. Dimming channels: Four individually-controllable dimming channels. Feedback on switching condition and brightness value. Dimmable brightness range can be set. Dimming behaviour and dimming characteristics can be parameterised. Soft switch-on and soft switch-off function Block function or forced setting function can be parameterised. Time functions (switch-on delay, switch-off delay, staircase light function). With the staircase light function, the reaction at the end of the switch-on time can be configured. Inclusion of a dimming channel in up to ten scenes is possible. The burning-in function allows for the start-up of new fluorescent lamps prescribed by lighting manufacturers. Switching actuator operation (optional): Independent switching of switch outputs A2 to A4. NO contact or NC contact operation. Feedback from the switching condition. Block function or forced setting function can be parameterised. Time functions (switch-on, switch-off delay, staircase light function - also with advance warning function). Can be integrated in the light scenes. Up to ten internal scenes per switching output are programmable. Cyclical monitoring of incoming switching telegram is configurable. Notes : Electronic ballasts generate very high current spikes. For this reason, use a switch-on current limiter or a separate load contact for with greater loads.