Earth-fault release, 0.03-3A, 3p, right

Vendor stock: No Minimal order quantity: 1
In stock price (excl. VAT):
295,11 €
This price is valid until 24.12.24
EAN: 4015081044153
MPN: 104605
Package: 1

Technical Information

Item condition New
Manufacture name Earth-fault release, 0.03-3A, 3p, right
Brand EATON
Categories Accessories (Automatics & control)
Country of origin CZ
Harmonized System Code 8538 9099 00
Delay adjustable Yes
Rated fault current 0.03-3 A
Rated control supply voltage at AC 50 Hz 200-415 V
Rated control supply voltage at AC 60 Hz 200-415 V
Rated control supply voltage at DC 0 V
Max. rated operation voltage Ue 415 V
Max. power on-delay time 30 ms

Packing details

Packing level 1 4015081044153

Description

Optional accessories for the circuit-breaker series NZM offers a comprehensive portfolio of application options for use world wide. The mounting is always flexible and easy thanks to the modular function groups. Notes: approved according to IEC/EN 60947-2 not UL/CSA approved. Suitable for use in three- and single-phase systems. Pulse current sensitive according to core-balance principle. For 3 and 4 pole NZM1(-4) circuit-breakers and switch-disconnectors N1(-4).mains voltage independent Ue = 200 .. 415 V 50/60 Hz. At I △n = 0.03 A: delay time t v always fixed setting to 10 ms. Warning message > 30 % I △n by yellow LED . Trip indication max. 2 auxiliary contacts (HIAFI) can be fitted by user: N/O = M22-K01, N/C = M22-K10 are reset via the reset button. If the trip-indicating auxiliary contact in the fault current block is used, the N/C contacts operates as a N/O contact and the N/C contact operates as an N/O contact. Double contact not permissible. Not in combination with insulated enclosure or main switch assembly kit for side panel mounting with mounting bracket. NZM1-XFI...R can not be used in combination with lower cover NZM1-XUSA.NZM1-XFI…U not in combination with shunt or undervoltage release, early-make auxiliary contacts . Rated ultimate short-circuit breaking capacity is determined by fitted NZM1, NS1. When using a switch-disconnector N1, by the back-up fuse to be used. See technical data. Can be used for: NZM1, N(S)1