Register to unlock your exclusive B2B prices and start shopping. Sign up now!
Variable frequency drive, 400 V AC, 3-phase, 5.8 A, 2.2 kW, IP20/NEMA 0, Radio interference suppression filter, Brake chopper, FS2 image 1
Variable frequency drive, 400 V AC, 3-phase, 5.8 A, 2.2 kW, IP20/NEMA 0, Radio interference suppression filter, Brake chopper, FS2 image 2
Variable frequency drive, 400 V AC, 3-phase, 5.8 A, 2.2 kW, IP20/NEMA 0, Radio interference suppression filter, Brake chopper, FS2 image 3
Variable frequency drive, 400 V AC, 3-phase, 5.8 A, 2.2 kW, IP20/NEMA 0, Radio interference suppression filter, Brake chopper, FS2 image 4
Variable frequency drive, 400 V AC, 3-phase, 5.8 A, 2.2 kW, IP20/NEMA 0, Radio interference suppression filter, Brake chopper, FS2 image 5
Variable frequency drive, 400 V AC, 3-phase, 5.8 A, 2.2 kW, IP20/NEMA 0, Radio interference suppression filter, Brake chopper, FS2 image 6
Variable frequency drive, 400 V AC, 3-phase, 5.8 A, 2.2 kW, IP20/NEMA 0, Radio interference suppression filter, Brake chopper, FS2 image 7
Variable frequency drive, 400 V AC, 3-phase, 5.8 A, 2.2 kW, IP20/NEMA 0, Radio interference suppression filter, Brake chopper, FS2 image 8
Variable frequency drive, 400 V AC, 3-phase, 5.8 A, 2.2 kW, IP20/NEMA 0, Radio interference suppression filter, Brake chopper, FS2 image 9
Variable frequency drive, 400 V AC, 3-phase, 5.8 A, 2.2 kW, IP20/NEMA 0, Radio interference suppression filter, Brake chopper, FS2 image 10
Variable frequency drive, 400 V AC, 3-phase, 5.8 A, 2.2 kW, IP20/NEMA 0, Radio interference suppression filter, Brake chopper, FS2 thumbnail 1
Variable frequency drive, 400 V AC, 3-phase, 5.8 A, 2.2 kW, IP20/NEMA 0, Radio interference suppression filter, Brake chopper, FS2 thumbnail 2
Variable frequency drive, 400 V AC, 3-phase, 5.8 A, 2.2 kW, IP20/NEMA 0, Radio interference suppression filter, Brake chopper, FS2 thumbnail 3
Variable frequency drive, 400 V AC, 3-phase, 5.8 A, 2.2 kW, IP20/NEMA 0, Radio interference suppression filter, Brake chopper, FS2 thumbnail 4
Variable frequency drive, 400 V AC, 3-phase, 5.8 A, 2.2 kW, IP20/NEMA 0, Radio interference suppression filter, Brake chopper, FS2 thumbnail 5
Variable frequency drive, 400 V AC, 3-phase, 5.8 A, 2.2 kW, IP20/NEMA 0, Radio interference suppression filter, Brake chopper, FS2 thumbnail 6
Variable frequency drive, 400 V AC, 3-phase, 5.8 A, 2.2 kW, IP20/NEMA 0, Radio interference suppression filter, Brake chopper, FS2 thumbnail 7
Variable frequency drive, 400 V AC, 3-phase, 5.8 A, 2.2 kW, IP20/NEMA 0, Radio interference suppression filter, Brake chopper, FS2 thumbnail 8
Variable frequency drive, 400 V AC, 3-phase, 5.8 A, 2.2 kW, IP20/NEMA 0, Radio interference suppression filter, Brake chopper, FS2 thumbnail 9
Variable frequency drive, 400 V AC, 3-phase, 5.8 A, 2.2 kW, IP20/NEMA 0, Radio interference suppression filter, Brake chopper, FS2 thumbnail 10

Variable frequency drive, 400 V AC, 3-phase, 5.8 A, 2.2 kW, IP20/NEMA 0, Radio interference suppression filter, Brake chopper, FS2

Vendor stock: No Minimal order quantity: 1
In stock price (excl. VAT):
471,02 €
This price is valid until 24.12.24
EAN: 4015081812516
MPN: 185752
Package: 1

Technical Information

Item condition New
Manufacture name Variable frequency drive, 400 V AC, 3-phase, 5.8 A, 2.2 kW, IP20/NEMA 0, Radio interference suppression filter, Brake chopper, FS2
Brand EATON
Categories Control gear
Country of origin GB
Width 107 mm
Height 231 mm
Depth 152 mm
With control element Yes
Number of digital inputs 4
Number of digital outputs 1
Number of analogue inputs 2
Number of analogue outputs 1
Supporting protocol for LON No
Number of HW-interfaces industrial Ethernet 0
Number of HW-interfaces RS-232 0
Number of HW-interfaces RS-422 0
Number of HW-interfaces RS-485 1
Number of HW-interfaces serial TTY 0
Number of HW-interfaces USB 0
Number of HW-interfaces parallel 0
Number of HW-interfaces other 0
With optical interface No
Supporting protocol for TCP/IP No
Supporting protocol for ASI No
Supporting protocol for PROFIBUS No
Supporting protocol for CAN Yes
Supporting protocol for INTERBUS No
Supporting protocol for KNX No
Supporting protocol for Modbus Yes
Supporting protocol for Data-Highway No
Supporting protocol for DeviceNet No
Supporting protocol for SUCONET No
Supporting protocol for other bus systems Yes
Degree of protection (IP) IP20
With PC connection Yes
Supporting protocol for SERCOS No
Supporting protocol for INTERBUS-Safety No
Mains voltage 380-480 V
Mains frequency 50/60 Hz
4-quadrant operation possible Yes
Number of interfaces PROFINET 0
Type of converter U converter
Number of phases output 3
Number of phases input 3
Integrated breaking resistance Yes
Application in industrial area permitted Yes
Application in domestic- and commercial area permitted Yes
Max. output frequency 500 Hz
Max. output at linear load at rated output voltage 2.2 kW
Max. output at quadratic load at rated output voltage 2.2 kW
Relative symmetric net voltage tolerance 10 %
Relative symmetric net frequency tolerance 10 %
Supporting protocol for AS-Interface Safety at Work No
Supporting protocol for DeviceNet Safety No
Supporting protocol for EtherNet/IP Yes
Supporting protocol for Foundation Fieldbus No
Supporting protocol for PROFINET CBA No
Supporting protocol for PROFINET IO No
Supporting protocol for PROFIsafe No
Supporting protocol for SafetyBUS p No
Max. output voltage 500 V
Nominal output current I2N 5.8 A
Supporting protocol for BACnet No
Degree of protection (NEMA) Other

Packing details

Packing level 1 4015081812516

Description

Variable frequency drive, Part group reference (e.g. DIL): DC1, Rated operational voltage: Ue = 400 V AC, 3-phase, 480 V AC, 3-phase, Output voltage with Ve: U2 = 400 V AC, 3-phase, 480 V AC, 3-phase, Mains voltage (50/60Hz): ULN = 380 (-10%) - 480 (+10%) V, Rated operational current At 150% overload: Ie = 5.8 A, Note: Rated operational current at an operating frequency of 16 kHz and an ambient air temperature of +50 °C, Note: Overload cycle for 60 s every 600 s, Assigned motor rating Note: for normal internally and externally ventilated 4 pole, three-phase asynchronous motors with 1500 rpm-1 at 50 Hz or 1800 min-1 at 60 Hz , Overload cycle for 60 s every 600 s, at 400 V, 50 Hz, Assigned motor rating 150 % Overload: P = 2.2 kW, 150 % Overload: IM = 5 A, Assigned motor rating Note: at 440 - 480 V, 60 Hz, Assigned motor rating 150 % Overload: P = 3 HP, Assigned motor rating 150 % Overload: IM = 4.8 A, Degree of Protection: IP20/NEMA 0, Interface/field bus (built-in): OP-Bus (RS485)/Modbus RTU, CANopen®, Fieldbus connection (optional): SmartWire-DT, Fitted with: Radio interference suppression filter, Brake chopper, 7-digital display assembly, Frame size: FS2, Standards: Specification for general requirements: IEC/EN 61800-2, EMC requirements: IEC/EN 61800-3 , Safety requirements: IEC/EN 61800-5-1

Similar items

Accessories

Similar items

Suitable for

Similar items
4015081683918 4015081684038 4015081785391 4015081785452 4015081945221 4015082695026 4015082695392 4015082715908 4015081785100 4015081819980
Accessories
4015081683918 4015081684038 4015081785391 4015081785452 4015081945221 4015082695026 4015082695392 4015082715908 4015081785100 4015081819980
Similar items
4015081656202 4015081656189 4015082715908 4015081819980 4015081655267 4015081655243 4015081655236 4015081785391 4015081785452 4015081684038
Suitable for
4015081683918 4015081684038 4015081785391 4015081785452 4015081819980 4015081945221 4015082695026 4015082695392 4015082715908 4015081785100