Technical Information
Item condition |
New |
Manufacture name |
Switching power supply unit 12V/12W |
Brand |
ELTAKO
|
Categories |
Power supply elements and devices, reactive power compensation
|
Country of origin |
CN |
Harmonized System Code |
8504 3180 00
|
Width |
18 mm |
Height |
58 mm |
Depth |
58 mm |
Voltage type of supply voltage |
AC |
Power output |
12 W |
Rail mounting possible |
Yes |
Wall mounting possible |
No |
1st secondary output voltage |
12 V |
Rated supply voltage at AC 50 Hz |
230 V |
Max. output current 1 |
1 A |
Packing details
Packing level 1 |
4010312315095, 4010312315095 |
Packing level 2 |
4010312315095 |
Packing level 3 |
4010312315095 |
Other Technical data
Built-in width |
18 mm |
Modular version |
Yes |
Suitable for safety functions |
- |
Width in number of modular spacings |
1 |
Output voltage stabilized |
Yes |
Type of electric connection |
Screw connection |
Stabilized |
Yes |
Degree of protection (IP) |
IP20 |
Direct mounting possible |
- |
Secondary voltage adjustable |
No |
Short-circuit-proof |
Yes |
Nominal value output voltage 1 |
12 V |
Downloads
Description
Switching power supply unit rated capacity 12W. Standby loss 0.2 watt only. Modular devices for DIN 60715 TH35 rail mounting. 1 module = 18mm wide, 58mm deep. If the total power demand of a Series 14 bus system is higher than 8W, other switching power supply units FSNT14-12V/12W are required. These are each supplying a group of actuators, which are separated with a disconnecting link on the FSNT14. The scope of delivery includes 1 disconnecting link TB14 1 module, 1 jumper 1.5 modules and a spacer DS14. At a load of more than 50% of the rated capacity and always if there are adjacent switching power supply units and dimmers a ventilation clearance of 1/2 module must be maintained with the spacers DS14. Therefore, this and a long jumper are included to the dimmers. Input voltage 230V (-20% bis +10%). Efficiency 83%. Stabilised output voltage ±1%, low residual ripple. Short-circuit proof. Overload protection and over-temperature switch-off by means of swichting off with automatic switching-on after fault clearance (autorecovery function). This switching power supply unit can also be used for producing a redundancy. Therefore only 1 FSNT14 should be plugged in parallel to the integrated power supply units into the FAM14 and FTS14KS and connected to a normal jumper. For an optimal load distribution, the FSNT14 should be placed as close as possible next to the last bus actuator.