Technical Information

Item condition New
Manufacture name Inverter Q2A, 200 V, ND: 6 A / 1.1 kW, HD: 5 A / 0.75 kW, IP20, max. o AA054052C
Brand Omron
Country of origin NL
Width 312 mm
Height 260 mm
Depth 176 mm
With control element Yes
Number of digital inputs 8
Number of digital outputs 3
Number of analogue inputs 3
Number of analogue outputs 2
Supporting protocol for LON No
Number of HW-interfaces industrial Ethernet 4
Number of HW-interfaces RS-232 0
Number of HW-interfaces RS-422 0
Number of HW-interfaces RS-485 1
Number of HW-interfaces serial TTY 0
Number of HW-interfaces USB 1
Number of HW-interfaces parallel 0
Number of HW-interfaces other 0
With optical interface No
Supporting protocol for TCP/IP Yes
Supporting protocol for ASI No
Supporting protocol for PROFIBUS Yes
Supporting protocol for CAN Yes
Supporting protocol for INTERBUS No
Supporting protocol for KNX No
Supporting protocol for Modbus Yes
Supporting protocol for Data-Highway No
Supporting protocol for DeviceNet Yes
Supporting protocol for SUCONET No
Supporting protocol for other bus systems Yes
Degree of protection (IP) IP20
With PC connection Yes
Supporting protocol for SERCOS No
Supporting protocol for INTERBUS-Safety No
Mains voltage 200-240 V
Mains frequency 50/60 Hz
4-quadrant operation possible Yes
Number of interfaces PROFINET 1
Type of converter Other
Number of phases output 3
Number of phases input 3
Integrated breaking resistance No
Application in industrial area permitted Yes
Application in domestic- and commercial area permitted Yes
Max. output frequency 590 Hz
Max. output at linear load at rated output voltage 0.75 kW
Max. output at quadratic load at rated output voltage 1.1 kW
Relative symmetric net voltage tolerance 10 %
Relative symmetric net frequency tolerance 5 %
Supporting protocol for AS-Interface Safety at Work No
Supporting protocol for DeviceNet Safety Yes
Supporting protocol for EtherNet/IP Yes
Supporting protocol for Foundation Fieldbus No
Supporting protocol for PROFINET CBA No
Supporting protocol for PROFINET IO Yes
Supporting protocol for PROFIsafe No
Supporting protocol for SafetyBUS p No
Max. output voltage 240 V
Nominal output current I2N 3.5 A
Supporting protocol for BACnet No
Degree of protection (NEMA) Other

Packing details

Packing level 1 4549734959216, 4549734959216

Downloads

Description

Inverter Q2A, 200 V, ND: 6 A / 1.1 kW, HD: 5 A / 0.75 kW, IP20, max. output freq. 590 Hz