Register to unlock your exclusive B2B prices and start shopping. Sign up now!
Lightning current and surge arresters, 12, 5 kA, L-(SU) N image 1
Lightning current and surge arresters, 12, 5 kA, L-(SU) N image 2
Lightning current and surge arresters, 12, 5 kA, L-(SU) N image 3
Lightning current and surge arresters, 12, 5 kA, L-(SU) N image 4
Lightning current and surge arresters, 12, 5 kA, L-(SU) N image 5
Lightning current and surge arresters, 12, 5 kA, L-(SU) N image 6
Lightning current and surge arresters, 12, 5 kA, L-(SU) N thumbnail 1
Lightning current and surge arresters, 12, 5 kA, L-(SU) N thumbnail 2
Lightning current and surge arresters, 12, 5 kA, L-(SU) N thumbnail 3
Lightning current and surge arresters, 12, 5 kA, L-(SU) N thumbnail 4
Lightning current and surge arresters, 12, 5 kA, L-(SU) N thumbnail 5
Lightning current and surge arresters, 12, 5 kA, L-(SU) N thumbnail 6

Lightning current and surge arresters, 12, 5 kA, L-(SU) N

In stock: No Vendor stock: No Minimal order quantity: 1
Price (excl. VAT):
39,08 €
This price is valid until 24.12.24
EAN: 4015081548842
MPN: 158306
Package: 1
Box: 12

Technical Information

Item condition New
Manufacture name Lightning current and surge arresters, 12, 5 kA, L-(SU) N
Brand EATON
Categories Lighting protection
Country of origin RO
Harmonized System Code 8536 5080 00
Mounting method DIN rail (top hat rail) 35 mm
Lightning impulse current (10/350 µs) 12.5 kA
Number of poles 1
Construction size 1 modular spacing
Voltage protection level 1.5 kV
Remote signalling No
Follow current extinguishing capability 0 kA
Max. continuous voltage AC 280 V
Nominal voltage AC 280 V
Nominal voltage DC 0 V
Test class Type 1 + 2
Voltage protection level L-N 0 kV
Signalling at the device Optic
Max. continuous voltage DC 0 V
Degree of protection (IP) IP20
Max. PV-voltage 0 V
Voltage protection level N-PE 0 kV
Integrated backup fuse No
Max. conductor cross section solid (solid, stranded) 25 mm²
Max. conductor cross section flexible (fine-strand) 35 mm²
Voltage protection level (DC+ - DC-) 0 kV
Voltage protection level (DC+/DC- - PE) 0 kV
Specific energy (W/R) 39.1 kJ/Ohm
Energy-coordinated protection effect with regard to the terminal equipment No
System configuration DC No
System configuration IT No
System configuration TN Yes
System configuration TN-C No
System configuration TN-S Yes
System configuration TT No
System configuration other Yes
System configuration TN-C-S No
Voltage protection level L-PE 1.5 kV
Max. overcurrent protection device, parallel connection (fuse) 0 A
Max. overcurrent protection device, series connection (fuse) 160 A
Voltage switching spark gap technology No
Overcurrent protected voltage tapping No

Packing details

Packing level 1 4015081548842
Packing level 2 9008790412608
Packing level 3 9008790412615

Description

For protecting consumer systems against transient overvoltages caused by direct and indirect lightning strikes and switching operations, use in accordance with IEC 60364-5-53 section 534, iI according to IEC 61643-1, SPD-type T1, T2 according to EN 61643-11, lightning protection classes III and IV as per IEC 62305