Register to unlock your exclusive B2B prices and start shopping. Sign up now!
Motor-protective circuit-breaker, 0.75 kW, 1.6 - 2.5 A, Push in terminals image 1
Motor-protective circuit-breaker, 0.75 kW, 1.6 - 2.5 A, Push in terminals image 2
Motor-protective circuit-breaker, 0.75 kW, 1.6 - 2.5 A, Push in terminals image 3
Motor-protective circuit-breaker, 0.75 kW, 1.6 - 2.5 A, Push in terminals image 4
Motor-protective circuit-breaker, 0.75 kW, 1.6 - 2.5 A, Push in terminals image 5
Motor-protective circuit-breaker, 0.75 kW, 1.6 - 2.5 A, Push in terminals image 6
Motor-protective circuit-breaker, 0.75 kW, 1.6 - 2.5 A, Push in terminals image 7
Motor-protective circuit-breaker, 0.75 kW, 1.6 - 2.5 A, Push in terminals image 8
Motor-protective circuit-breaker, 0.75 kW, 1.6 - 2.5 A, Push in terminals image 9
Motor-protective circuit-breaker, 0.75 kW, 1.6 - 2.5 A, Push in terminals image 10
Motor-protective circuit-breaker, 0.75 kW, 1.6 - 2.5 A, Push in terminals image 11
Motor-protective circuit-breaker, 0.75 kW, 1.6 - 2.5 A, Push in terminals image 12
Motor-protective circuit-breaker, 0.75 kW, 1.6 - 2.5 A, Push in terminals image 13
Motor-protective circuit-breaker, 0.75 kW, 1.6 - 2.5 A, Push in terminals image 14
Motor-protective circuit-breaker, 0.75 kW, 1.6 - 2.5 A, Push in terminals image 15
Motor-protective circuit-breaker, 0.75 kW, 1.6 - 2.5 A, Push in terminals image 16
Motor-protective circuit-breaker, 0.75 kW, 1.6 - 2.5 A, Push in terminals thumbnail 1
Motor-protective circuit-breaker, 0.75 kW, 1.6 - 2.5 A, Push in terminals thumbnail 2
Motor-protective circuit-breaker, 0.75 kW, 1.6 - 2.5 A, Push in terminals thumbnail 3
Motor-protective circuit-breaker, 0.75 kW, 1.6 - 2.5 A, Push in terminals thumbnail 4
Motor-protective circuit-breaker, 0.75 kW, 1.6 - 2.5 A, Push in terminals thumbnail 5
Motor-protective circuit-breaker, 0.75 kW, 1.6 - 2.5 A, Push in terminals thumbnail 6
Motor-protective circuit-breaker, 0.75 kW, 1.6 - 2.5 A, Push in terminals thumbnail 7
Motor-protective circuit-breaker, 0.75 kW, 1.6 - 2.5 A, Push in terminals thumbnail 8
Motor-protective circuit-breaker, 0.75 kW, 1.6 - 2.5 A, Push in terminals thumbnail 9
Motor-protective circuit-breaker, 0.75 kW, 1.6 - 2.5 A, Push in terminals thumbnail 10
Motor-protective circuit-breaker, 0.75 kW, 1.6 - 2.5 A, Push in terminals thumbnail 11
Motor-protective circuit-breaker, 0.75 kW, 1.6 - 2.5 A, Push in terminals thumbnail 12
Motor-protective circuit-breaker, 0.75 kW, 1.6 - 2.5 A, Push in terminals thumbnail 13
Motor-protective circuit-breaker, 0.75 kW, 1.6 - 2.5 A, Push in terminals thumbnail 14
Motor-protective circuit-breaker, 0.75 kW, 1.6 - 2.5 A, Push in terminals thumbnail 15
Motor-protective circuit-breaker, 0.75 kW, 1.6 - 2.5 A, Push in terminals thumbnail 16

Motor-protective circuit-breaker, 0.75 kW, 1.6 - 2.5 A, Push in terminals

In stock: No Vendor stock: No Minimal order quantity: 1
Price (excl. VAT):
45,46 €
This price is valid until 31.12.25
EAN: 4015081972388
MPN: 199154
Package: 1

Technical Information

Item condition New
Manufacture name Motor-protective circuit-breaker, 0.75 kW, 1.6 - 2.5 A, Push in terminals
Brand EATON
Categories Motor protection circuit-breakers
Country of origin DE
Harmonized System Code 8536 2010 00
Width 45 mm
Height 109 mm
Depth 75 mm
Rated operation power at AC-3, 400 V 0.75 kW
With integrated auxiliary switch No
Rated permanent current Iu 2.5 A
With integrated under voltage release No
Number of poles 3
Rated operating voltage 690 V
Overload release current setting 2.5 A
Degree of protection (IP) IP20
With thermal protection No
Type of electrical connection of main circuit Spring clamp connection
Type of control element Turn button
Switch off technique Thermomagnetic
Rated operation power at AC-3, 230 V 0.37 kW
Rated short-circuit breaking capacity lcu at 400 V, AC 150 kA
Adjustment range undelayed short-circuit release 39 A
Phase failure sensitive Yes
Device construction Built-in device fixed built-in technique

Packing details

Packing level 1 4015081972388

Description

Motor-protective circuit-breaker, IEC/EN 60947, VDE 0660, Overload releases 1.6 - 2.5 A: max. 38.8 A, Switch off technique Thermomagnetic, With thermal protection Yes, Phase failure sensitive Yes, Rated permanent current Iu 2.5 A, Rated operation power at AC-3, 230 V 0.37 kW, Rated operation power at AC-3, 400 V 0.75 kW, Type of control element Turn button, Number of poles 3: Rated short-circuit breaking capacity lcu at 400 V, AC 150 kA, Device IP20, Terminations IP20, Storage - 40 - 80 °C, Open -25 - +55 °C, Direction of incoming supply as required

Similar items

Accessories

Similar items

Suitable for

Similar items
4015081974177 4015081974184 4015081974191 4015081974207 4015081974214 4015081974221 4015081974238 4015081974245 4015081974252 4015081978687 4015081978694 4015081978700 4015081978717 4015081978724 4015081978779 4015081983360 4015082035990
Accessories
4015081974177 4015081974184 4015081974191 4015081974207 4015081974214 4015081974221 4015081974238 4015081974245 4015081974252 4015081978687 4015081978694 4015081978700 4015081978717 4015081978724 4015081978779 4015081983360 4015082035990 4015081974153
Similar items
4015081974108 4015081974252 4015081974221 4015081978717 4015081978700 4015081974092 4015081974177 4015081978724 4015081974191 4015081974184 4015081974122 4015081978687 4015081974214 4015081983360 4015081974238 4015081974139 4015081974115
Suitable for
4015081974207 4015081974214 4015081974221 4015081974238 4015081974245 4015081974252 4015081978687 4015081978694 4015081978700 4015081978717 4015081978724 4015081978779 4015081983360 4015082035990 4015080308515 4015081059027 4015081059034