Register to unlock your exclusive B2B prices and start shopping. Sign up now!
NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 160A, 3p, Screw terminal, earth-fault protection and zone selectivity, plug-in tec image 1
NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 160A, 3p, Screw terminal, earth-fault protection and zone selectivity, plug-in tec image 2
NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 160A, 3p, Screw terminal, earth-fault protection and zone selectivity, plug-in tec image 3
NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 160A, 3p, Screw terminal, earth-fault protection and zone selectivity, plug-in tec image 4
NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 160A, 3p, Screw terminal, earth-fault protection and zone selectivity, plug-in tec image 5
NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 160A, 3p, Screw terminal, earth-fault protection and zone selectivity, plug-in tec image 6
NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 160A, 3p, Screw terminal, earth-fault protection and zone selectivity, plug-in tec image 7
NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 160A, 3p, Screw terminal, earth-fault protection and zone selectivity, plug-in tec image 8
NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 160A, 3p, Screw terminal, earth-fault protection and zone selectivity, plug-in tec image 9
NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 160A, 3p, Screw terminal, earth-fault protection and zone selectivity, plug-in tec image 10
NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 160A, 3p, Screw terminal, earth-fault protection and zone selectivity, plug-in tec image 11
NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 160A, 3p, Screw terminal, earth-fault protection and zone selectivity, plug-in tec thumbnail 1
NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 160A, 3p, Screw terminal, earth-fault protection and zone selectivity, plug-in tec thumbnail 2
NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 160A, 3p, Screw terminal, earth-fault protection and zone selectivity, plug-in tec thumbnail 3
NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 160A, 3p, Screw terminal, earth-fault protection and zone selectivity, plug-in tec thumbnail 4
NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 160A, 3p, Screw terminal, earth-fault protection and zone selectivity, plug-in tec thumbnail 5
NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 160A, 3p, Screw terminal, earth-fault protection and zone selectivity, plug-in tec thumbnail 6
NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 160A, 3p, Screw terminal, earth-fault protection and zone selectivity, plug-in tec thumbnail 7
NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 160A, 3p, Screw terminal, earth-fault protection and zone selectivity, plug-in tec thumbnail 8
NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 160A, 3p, Screw terminal, earth-fault protection and zone selectivity, plug-in tec thumbnail 9
NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 160A, 3p, Screw terminal, earth-fault protection and zone selectivity, plug-in tec thumbnail 10
NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 160A, 3p, Screw terminal, earth-fault protection and zone selectivity, plug-in tec thumbnail 11

NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 160A, 3p, Screw terminal, earth-fault protection and zone selectivity, plug-in tec

In stock: No Vendor stock: No Minimal order quantity: 1
Price (excl. VAT):
1 279,27 €
This price is valid until 24.12.24
EAN: 4015081927517
MPN: 192200
Package: 1

Technical Information

Item condition New
Manufacture name NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 160A, 3p, Screw terminal, earth-fault protection and zone selectivity, plug-in tec
Brand EATON
Categories Breakers
Country of origin RO
Harmonized System Code 8536 2090 00
Number of auxiliary contacts as normally open contact 0
Number of auxiliary contacts as normally closed contact 0
Rated permanent current Iu 160 A
With integrated under voltage release No
Number of poles 3
Overload release current setting 64-160 A
Number of auxiliary contacts as change-over contact 0
Rated voltage 690 V
Degree of protection (IP) IP20
Position of connection for main current circuit Connection at separate chassis part
Motor drive integrated No
Type of electrical connection of main circuit Other
Type of control element Rocker lever
With switched-off indicator No
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz 150 kA
Adjustment range short-term delayed short-circuit release 2-10 A
Adjustment range undelayed short-circuit release 2-18 A
Suitable for DIN rail (top hat rail) mounting No
Integrated earth fault protection Yes
Motor drive optional Yes
Device construction Built-in device plug-in technique
DIN rail (top hat rail) mounting optional No
Complete device with protection unit Yes

Packing details

Packing level 1 4015081927517

Description

The xEffect NZM...-PX...-TZ circuit breaker range with power expert release (PXR) electronic triggering system covers use cases for full range protection including earth fault protection with only four compact sizes and is suitable for the IEC market. The integrated energy measuring function supplies currents, voltages and active energy (kWh) with accuracy class 1 according to IEC 61557-12. Zone selectivity for extended protection included. Test function and settings via micro USB port directly on the switch. Modular function groups always make mounting flexible and may be supplemented by the comprehensive range of accessories . R.m.s. value measurement and thermal memory.