Register to unlock your exclusive B2B prices and start shopping. Sign up now!
OVR T1-T2 N 50-275s C QS Surge Protective Device image 1
OVR T1-T2 N 50-275s C QS Surge Protective Device image 2
MD99 image 3
OVR T1-T2 N 50-275s C QS Surge Protective Device image 4
OVR T1-T2 N 50-275s C QS Surge Protective Device image 5
OVR T1-T2 N 50-275s C QS Surge Protective Device thumbnail 1
OVR T1-T2 N 50-275s C QS Surge Protective Device thumbnail 2
MD99 thumbnail 3
OVR T1-T2 N 50-275s C QS Surge Protective Device thumbnail 4
OVR T1-T2 N 50-275s C QS Surge Protective Device thumbnail 5

OVR T1-T2 N 50-275s C QS Surge Protective Device

In stock: No Vendor stock: No Minimal order quantity: 1
Price (excl. VAT):
78,80 € per pcs
This price is valid until 01.01.25
EAN: 3660308525048
MPN: 2CTB815710R2700
Package: 1
Box: 5

Technical Information

Item condition New
Manufacture name OVR T1-T2 N 50-275s C QS Surge Protective Device
Brand ABB
Categories Lighting protection
Harmonized System Code 8536 3090 00
Mounting method DIN rail (top hat rail) 35 mm
Lightning impulse current (10/350 µs) 50 kA
Number of poles 1
Construction size 1 modular spacing
Voltage protection level 1 kV
Remote signalling No
Follow current extinguishing capability 0 kA
Max. continuous voltage AC 255 V
Nominal voltage AC 230 V
Nominal voltage DC 0 V
Test class Type 1 + 2
Voltage protection level L-N 0 kV
Signalling at the device None
Max. continuous voltage DC 0 V
Degree of protection (IP) IP20
Max. PV-voltage 0 V
Voltage protection level N-PE 1 kV
Integrated backup fuse No
Max. conductor cross section solid (solid, stranded) 25 mm²
Max. conductor cross section flexible (fine-strand) 16 mm²
Voltage protection level (DC+ - DC-) 0 kV
Voltage protection level (DC+/DC- - PE) 0 kV
Specific energy (W/R) 0 kJ/Ohm
Energy-coordinated protection effect with regard to the terminal equipment No
System configuration DC No
System configuration IT No
System configuration TN No
System configuration TN-C No
System configuration TN-S Yes
System configuration TT Yes
System configuration other No
System configuration TN-C-S No
Voltage protection level L-PE 1.4 kV
Max. overcurrent protection device, parallel connection (fuse) -1 A
Max. overcurrent protection device, series connection (fuse) -1 A
Voltage switching spark gap technology FALSE
Overcurrent protected voltage tapping FALSE

Packing details

Packing level 1 3660308525048
Packing level 2 3660308525048, 3660308525048

Downloads

Description

OVR T1-T2 12.5-275s C QS Surge Protective Device