Register to unlock your exclusive B2B prices and start shopping. Sign up now!
Phase imbalance monitoring relays, 300 - 500 V AC, 50/60 Hz image 1
Phase imbalance monitoring relays, 300 - 500 V AC, 50/60 Hz image 2
Phase imbalance monitoring relays, 300 - 500 V AC, 50/60 Hz image 3
Phase imbalance monitoring relays, 300 - 500 V AC, 50/60 Hz image 4
Phase imbalance monitoring relays, 300 - 500 V AC, 50/60 Hz thumbnail 1
Phase imbalance monitoring relays, 300 - 500 V AC, 50/60 Hz thumbnail 2
Phase imbalance monitoring relays, 300 - 500 V AC, 50/60 Hz thumbnail 3
Phase imbalance monitoring relays, 300 - 500 V AC, 50/60 Hz thumbnail 4

Phase imbalance monitoring relays, 300 - 500 V AC, 50/60 Hz

In stock: No Vendor stock: No Minimal order quantity: 1
Price (excl. VAT):
133,35 €
This price is valid until 24.12.25
EAN: 4015081787982
MPN: 184762
Package: 1

Technical Information

Item condition New
Manufacture name Phase imbalance monitoring relays, 300 - 500 V AC, 50/60 Hz
Brand EATON
Categories Relays
Country of origin DE
Harmonized System Code 8536 4900 00
Width 22.5 mm
Height 85.6 mm
Depth 103.7 mm
Voltage measuring range 300-500 V
With detachable clamps No
Phase sequence monitoring Yes
Phase failure detection Yes
Function under voltage detection No
Function over voltage detection No
Phase imbalance monitoring Yes
Type of electric connection Screw connection
Rated control supply voltage at AC 50 Hz 300-500 V
Rated control supply voltage at AC 60 Hz 300-500 V
Rated control supply voltage at DC 0 V
Max. permitted delay-on energization time 30 s
Min. adjustable delay-on energization time 0.1 s
Max. permitted off-delay time 0 s
Min. adjustable off-delay time 0 s
Voltage type for actuating AC
Number of contacts as normally closed contact 0
Number of contacts as normally open contact 0
Number of contacts as change-over contact 2

Packing details

Packing level 1 4015081787982

Description

Phase imbalance monitoring relays, Product range: EMR Measuring and monitoring relays, Power supply from the measuring circuit, On delay: None = 0 or adjustable from 0.1 to 30 s, Imbalance threshold values adjustable 2 - 25 % of mean value of phase voltages, Monitoring voltage per phase: UN= 300 - 500 V AC, 50/60 Hz V AC, Monitoring of: Phase sequence, Phase failure, Imbalance, Adjustable threshold values: Imbalance, Supply voltage: 300 - 500 V AC, 50/60 Hz, Mounting position: As required, Fixing: Snap fixing, top-hat rail IEC/EN 60715, Width: 22.5 mm, Standards: IEC/EN 60255-6, IEC255-6, UL, CE