Technical Information
Item condition |
New |
Manufacture name |
Powerline actuator 1 channel with sensor input 230V |
Brand |
ELTAKO
|
Categories |
Sensors
|
Country of origin |
CN |
Harmonized System Code |
8526 9200 00
|
Mounting method |
Flush mounted (plaster) |
Rated current |
10 A |
Output power |
2000 W |
Rated operating voltage |
230 V |
Bus system KNX |
No |
Bus system radio frequent |
No |
Bus system Powernet |
Yes |
Max. switching power |
2000 W |
With bus connection |
Yes |
Max. number of switching contacts |
1 |
Max. switching current |
10 A |
Other bus systems |
None |
Bus system LON |
No |
Suitable for C-load |
Yes |
Different phases connectable |
No |
Local operation/hand operation |
Yes |
With LED indication |
Yes |
Modular expandability |
No |
Bus system KNX radio |
No |
Radio frequent bidirectional |
No |
Bus module detachable |
No |
Min. depth of built-in installation box |
25 mm |
Max. switching power LED |
400 W |
Packing details
Packing level 1 |
4010312316665, 4010312316665 |
Packing level 2 |
4010312316665 |
Packing level 3 |
4010312316665 |
Downloads
Description
Powerline actuator with 1 channel with sensor input. 53x43mm, 25mm deep, for mounting in 58mm switch boxes. Used as impulse switch or relay. 1 NO contact not potential free 10A/250V AC, incandescent lamps 2000 watts. Sensor input 230V. Standby loss only 0,5 watt. To control and switch at the same place. Two rotary switches are located on the front for address assignment: The left rotary switch defines the group address g with 16 alphabetical values from A to P. The right rotary switch defines the element address e with 16 numerical values from 0 to 15. Above it is a slide switch which acts as a configuration switch with positions 0, 1 and 2. Position 0: Sensor input functions as pushbutton (impulse switch). Position 1: Sensor input functions as NO contact (relay). Position 2: A change-over switch is evaluated as a pushbutton. All entries and configurations can also be accessed via the mains using the PC software SIENNA Professional. This means that another configuration can also be set that is not available via the rotary switches: Position 3: Sensor input acts as NO contact (relay inverse). To the left of the rotary switches is a red LED which indicates all activities. Next to it is a reset pushbutton and to the right of that is a service pin. For functions, please refer to the operating instructions. The terminals located above are plug-in terminals for conductor cross-sections of 0.2mm² to 1.5mm².