Register to unlock your exclusive B2B prices and start shopping. Sign up now!
Plug-in surge arresters, 1pole+N, 460VAC, 20 kA image 1
Plug-in surge arresters, 1pole+N, 460VAC, 20 kA image 2
Plug-in surge arresters, 1pole+N, 460VAC, 20 kA image 3
Plug-in surge arresters, 1pole+N, 460VAC, 20 kA image 4
Plug-in surge arresters, 1pole+N, 460VAC, 20 kA image 5
Plug-in surge arresters, 1pole+N, 460VAC, 20 kA image 6
Plug-in surge arresters, 1pole+N, 460VAC, 20 kA thumbnail 1
Plug-in surge arresters, 1pole+N, 460VAC, 20 kA thumbnail 2
Plug-in surge arresters, 1pole+N, 460VAC, 20 kA thumbnail 3
Plug-in surge arresters, 1pole+N, 460VAC, 20 kA thumbnail 4
Plug-in surge arresters, 1pole+N, 460VAC, 20 kA thumbnail 5
Plug-in surge arresters, 1pole+N, 460VAC, 20 kA thumbnail 6

Plug-in surge arresters, 1pole+N, 460VAC, 20 kA

In stock: No Vendor stock: No Minimal order quantity: 1
Price (excl. VAT):
76,47 €
This price is valid until 24.12.24
EAN: 4015081641147
MPN: 167625
Package: 1
Box: 60

Technical Information

Item condition New
Manufacture name Plug-in surge arresters, 1pole+N, 460VAC, 20 kA
Brand EATON
Categories Lighting protection
Country of origin RO
Harmonized System Code 8536 5080 00
Mounting method DIN rail (top hat rail) 35 mm
With remote signalling contact No
Number of conductors (without earthing) 1
Construction size 2 modular spacing
Voltage protection level 2.2 kV
Max. continuous voltage AC 460 V
Nominal discharge surge current (8/20) 20 kA
Nominal voltage AC 460 V
Nominal voltage DC 0 V
Category type 2 Yes
Voltage protection level L-N 0 kV
Signalling at the device Optic
Max. continuous voltage DC 0 V
Degree of protection (IP) IP20
Max. PV-voltage 0 V
Voltage protection level N-PE 0 kV
Integrated backup fuse No
Max. conductor cross section solid (solid, stranded) 25 mm²
Max. conductor cross section flexible (fine-strand) 35 mm²
System configuration DC No
System configuration IT Yes
System configuration TN Yes
System configuration TN-C No
System configuration TN-S Yes
System configuration TT Yes
System configuration other Yes
System configuration TN-C-S No
Max. discharge surge current (8/20) 40 kA
Short-circuit breaking capacity (Isccr) 0 kA
Max. overcurrent protection device, parallel connection (fuse) 0 A
Max. overcurrent protection device, series connection (fuse) 125 A
Integrated short-circuit protection No
Integrated short-circuit protection selective to fuse gG 0 A
Leakage-current free No

Packing details

Packing level 1 4015081641147
Packing level 2 9008790475030

Description

For protecting consumer systems against transient overvoltages caused by indirect lightning strikes and switching operations, test class II according to IEC 61643-1+A1, SPD-type T2 according to EN 61643-11, SPC-S-HK auxiliary contact for remote signaling can be added, can be bussed with all Xtra Combinations switchgear caused by indirect lightning strikes and switching operations, test class II according to IEC 61643-1+A1, SPD-type T2 according to EN 61643-11, SPC-S-HK auxiliary contact for remote signaling can be added, can be bussed with all Xtra Combinations switchgear