Register to unlock your exclusive B2B prices. Register now
Plug-in surge arresters, 3pole+N, 460VAC, 20 kA image 1
Plug-in surge arresters, 3pole+N, 460VAC, 20 kA image 2
Plug-in surge arresters, 3pole+N, 460VAC, 20 kA image 3
Plug-in surge arresters, 3pole+N, 460VAC, 20 kA image 4
Plug-in surge arresters, 3pole+N, 460VAC, 20 kA image 5

Plug-in surge arresters, 3pole+N, 460VAC, 20 kA

In stock price (excl. VAT):
130,56 €
This price is valid until 2024-12-31
Price per m: 130,56 €
EAN: 4015081641154
MPN: 167626
Our warehouse: No Vendor stock: No
Per package: 1 Per box: 30 Per pallet: N/A
Technical data
Item condition New
Brand EATON
Categories Lighting protection
Country of origin RO
Harmonized System Code 8536 5080 00
Mounting method DIN rail (top hat rail) 35 mm
With remote signalling contact No
Number of conductors (without earthing) 3.000
Construction size 4 modular spacing
Voltage protection level 2.200 kV
Max. continuous voltage AC 460.000 V
Nominal discharge surge current (8/20) 20.000 kA
Nominal voltage AC 460.000 V
Nominal voltage DC 0.000 V
Category type 2 Yes
Voltage protection level L-N 0.000 kV
Signalling at the device Optic
Max. continuous voltage DC 0.000 V
Degree of protection (IP) IP20
Max. PV-voltage 0.000 V
Voltage protection level N-PE 0.000 kV
Integrated backup fuse No
Max. conductor cross section solid (solid, stranded) 25.000 mm²
Max. conductor cross section flexible (fine-strand) 35.000 mm²
System configuration DC No
System configuration IT Yes
System configuration TN Yes
System configuration TN-C No
System configuration TN-S Yes
System configuration TT Yes
System configuration other Yes
System configuration TN-C-S Yes
Max. discharge surge current (8/20) 40.000 kA
Short-circuit breaking capacity (Isccr) 0.000 kA
Max. overcurrent protection device, parallel connection (fuse) 0.000 A
Max. overcurrent protection device, series connection (fuse) 125.000 A
Integrated short-circuit protection No
Integrated short-circuit protection selective to fuse gG 0.000 A
Leakage-current free No
Packing details
Packing level 1 4015081641154
Packing level 2 9008790475047
Description
For protecting consumer systems against transient overvoltages caused by indirect lightning strikes and switching operations, test class II according to IEC 61643-1+A1, SPD-type T2 according to EN 61643-11, SPC-S-HK auxiliary contact for remote signaling can be added, can be bussed with all Xtra Combinations switchgear caused by indirect lightning strikes and switching operations, test class II according to IEC 61643-1+A1, SPD-type T2 according to EN 61643-11, SPC-S-HK auxiliary contact for remote signaling can be added, can be bussed with all Xtra Combinations switchgear