Register to unlock your exclusive B2B prices and start shopping. Sign up now!
Reversing starter, 24 V DC, 0,18 - 2,4 A, Push in terminals image 1
Reversing starter, 24 V DC, 0,18 - 2,4 A, Push in terminals image 2
Reversing starter, 24 V DC, 0,18 - 2,4 A, Push in terminals image 3
Reversing starter, 24 V DC, 0,18 - 2,4 A, Push in terminals image 4
Reversing starter, 24 V DC, 0,18 - 2,4 A, Push in terminals image 5
Reversing starter, 24 V DC, 0,18 - 2,4 A, Push in terminals image 6
Reversing starter, 24 V DC, 0,18 - 2,4 A, Push in terminals thumbnail 1
Reversing starter, 24 V DC, 0,18 - 2,4 A, Push in terminals thumbnail 2
Reversing starter, 24 V DC, 0,18 - 2,4 A, Push in terminals thumbnail 3
Reversing starter, 24 V DC, 0,18 - 2,4 A, Push in terminals thumbnail 4
Reversing starter, 24 V DC, 0,18 - 2,4 A, Push in terminals thumbnail 5
Reversing starter, 24 V DC, 0,18 - 2,4 A, Push in terminals thumbnail 6

Reversing starter, 24 V DC, 0,18 - 2,4 A, Push in terminals

In stock: No Vendor stock: No Minimal order quantity: 1
Price (excl. VAT):
136,41 €
This price is valid until 24.12.25
EAN: 4015081930890
MPN: 192392
Package: 1

Technical Information

Item condition New
Manufacture name Reversing starter, 24 V DC, 0,18 - 2,4 A, Push in terminals
Brand EATON
Categories Modular switches
Country of origin DE
Harmonized System Code 8536 5080 00
Width 22.5 mm
Height 99 mm
Depth 114.5 mm
With transformer No
Rated operation power at AC-3, 400 V 0.75 kW
Number of command positions 0
Number of auxiliary contacts as normally open contact 1
Number of auxiliary contacts as normally closed contact 1
Suitable for emergency stop No
Rated operation current Ie 2.4 A
Number of indicator lights 0
Overload release current setting 0.18-3 A
Supporting protocol for LON No
Supporting protocol for TCP/IP No
Supporting protocol for ASI No
Supporting protocol for PROFIBUS No
Supporting protocol for CAN No
Supporting protocol for INTERBUS No
Supporting protocol for Modbus No
Supporting protocol for Data-Highway No
Supporting protocol for DeviceNet No
Supporting protocol for SUCONET No
Supporting protocol for other bus systems No
External reset possible No
Rail mounting possible Yes
Rated control supply voltage at AC 50 Hz 0 V
Rated control supply voltage at AC 60 Hz 0 V
Rated control supply voltage at DC 24 V
Degree of protection (IP) IP20
Supporting protocol for SERCOS No
Supporting protocol for INTERBUS-Safety No
Release class CLASS 10
With short-circuit release No
With fuse No
Type of electrical connection of main circuit Spring clamp connection
Type of electrical connection for auxiliary- and control current circuit Spring clamp connection
Supporting protocol for AS-Interface Safety at Work No
Supporting protocol for DeviceNet Safety No
Supporting protocol for EtherNet/IP No
Supporting protocol for Foundation Fieldbus No
Supporting protocol for PROFINET CBA No
Supporting protocol for PROFINET IO No
Supporting protocol for PROFIsafe No
Supporting protocol for SafetyBUS p No
Voltage type for actuating DC
Type of motor starter Reversing starter
Rated operation power at AC-3, 230 V, 3-phase 0.37 kW
Rated power, 460 V, 60 Hz, 3-phase 0 kW
Rated power, 575 V, 60 Hz, 3-phase 0 kW
Rated operation current at AC-3, 400 V 2.4 A
Ambient temperature, upper operating limit 70 °C
Temperature compensated overload protection Yes
Rated conditional short-circuit current, type 2, 400 V 0 A
Rated conditional short-circuit current, type 2, 230 V 0 A
Rated conditional short-circuit current, type 1, 480 Y/277 V 0 A
Rated conditional short-circuit current, type 1, 600 Y/347 V 0 A
Degree of protection (NEMA) Other
Coordination class according to IEC 60947-4-3 Class 1

Packing details

Packing level 1 4015081930890

Description

Reversing starter, Product range: Electronic motor starter, Description: DOL starting, Reversing start, Motor protection, Circuit design: safety output stage with bypass, three-phase disconnect., Max. motor rating for three-phase motors, 50 - 60 Hz AC-53a 380 V 400 V 415 V: P= 0.06 - 0.75 kW, Setting range of overload releases: Ir= 0,18 - 2,4 A_x, Actuating voltage: 24 V DC, Connection technique: Push in terminals, Connection to SmartWire-DT: no, Mounting position: Vertical, Motor feeder at bottom, Standards: IEC/EN 60947-4-2, UL508