Item condition |
New |
Manufacture name |
SIMATIC DP, CPU 1516PRO F-2 PN for ... |
Brand |
Siemens
|
Categories |
Programmable logic controllers
|
Country of origin |
DE |
Harmonized System Code |
8537 1091 00
|
Width |
135 mm |
Height |
130 mm |
Depth |
65 mm |
Suitable for safety functions |
Yes |
Supporting protocol for LON |
No |
Number of HW-interfaces industrial Ethernet |
2 |
Number of HW-interfaces RS-232 |
0 |
Number of HW-interfaces RS-422 |
0 |
Number of HW-interfaces RS-485 |
0 |
Number of HW-interfaces serial TTY |
0 |
Number of HW-interfaces USB |
0 |
Number of HW-interfaces parallel |
0 |
Number of HW-interfaces other |
0 |
With optical interface |
No |
Type of voltage (input voltage) |
DC |
Supporting protocol for TCP/IP |
Yes |
Supporting protocol for ASI |
No |
Supporting protocol for PROFIBUS |
No |
Supporting protocol for CAN |
No |
Supporting protocol for INTERBUS |
No |
Supporting protocol for KNX |
No |
Supporting protocol for Modbus |
Yes |
Supporting protocol for Data-Highway |
No |
Supporting protocol for DeviceNet |
No |
Supporting protocol for SUCONET |
No |
Supporting protocol for other bus systems |
No |
Number of slots |
16 |
With pluggable modules, digital I/O |
Yes |
With pluggable modules, analogue I/O |
Yes |
With pluggable modules, communication modules |
Yes |
With pluggable modules, function and technology modules |
Yes |
With pluggable modules, central modules |
Yes |
With pluggable modules, others |
Yes |
With potential separation |
- |
With integrated power supply |
No |
Type of electric connection |
Plug-in connection |
Rail mounting possible |
Yes |
With bus coupler for modular station connection |
Yes |
Explosion safety category for gas |
ATEX gas-ex-protection, Cat. 3G |
Explosion safety category for dust |
None |
Fieldbus connection over separate bus coupler possible |
Yes |
System accessory |
Yes |
Appendant operation agent (Ex ia) |
No |
Appendant operation agent (Ex ib) |
No |
Degree of protection (IP) |
IP65/IP67 |
Supporting protocol for SERCOS |
No |
Supporting protocol for INTERBUS-Safety |
No |
Number of interfaces PROFINET |
2 |
Number of HW-interfaces Wireless |
0 |
Output voltage at AC 50 Hz |
UN V |
Output voltage at AC 60 Hz |
UN V |
Output voltage at DC |
UN V |
Front built-in possible |
No |
Rack-assembly possible |
No |
Wall mounting/direct mounting |
Yes |
Input voltage at AC 50 Hz |
UN V |
Input voltage at AC 60 Hz |
UN V |
Input voltage at DC |
20.4-28.8 V |
Radio standard Bluetooth |
No |
Radio standard Wi-Fi 802.11 |
No |
IO link master |
No |
Max. output current AC 50 Hz |
UN A |
Max. output current AC 60 Hz |
UN A |
Max. output current DC |
UN A |
Max. input current AC 50 Hz |
UN A |
Max. input current AC 60 Hz |
UN A |
Max. input current DC |
0.4 A |
Performance level according to EN ISO 13849-1 |
Level e |
Supporting protocol for AS-Interface Safety at Work |
No |
Supporting protocol for DeviceNet Safety |
No |
Supporting protocol for EtherNet/IP |
No |
Supporting protocol for Foundation Fieldbus |
No |
Supporting protocol for PROFINET CBA |
No |
Supporting protocol for PROFINET IO |
Yes |
Supporting protocol for PROFIsafe |
Yes |
Supporting protocol for SafetyBUS p |
No |
Radio standard GPRS |
No |
Radio standard GSM |
No |
Radio standard UMTS |
No |
SIL according to IEC 61508 |
3 |