Register to unlock your exclusive B2B prices and start shopping. Sign up now!
SPD type 1+2, 3 phase/3 varistors+1 spark-gap/260V Max./remote signal. (7P.04.8.260.1025) image 1
SPD type 1+2, 3 phase/3 varistors+1 spark-gap/260V Max./remote signal. (7P.04.8.260.1025) image 2
SPD type 1+2, 3 phase/3 varistors+1 spark-gap/260V Max./remote signal. (7P.04.8.260.1025) image 3
SPD type 1+2, 3 phase/3 varistors+1 spark-gap/260V Max./remote signal. (7P.04.8.260.1025) thumbnail 1
SPD type 1+2, 3 phase/3 varistors+1 spark-gap/260V Max./remote signal. (7P.04.8.260.1025) thumbnail 2
SPD type 1+2, 3 phase/3 varistors+1 spark-gap/260V Max./remote signal. (7P.04.8.260.1025) thumbnail 3

SPD type 1+2, 3 phase/3 varistors+1 spark-gap/260V Max./remote signal. (7P.04.8.260.1025)

In stock: No Vendor stock: No Minimal order quantity: 1
Price (excl. VAT):
420,587 € per pcs
This price is valid until 31.12.24
EAN: 8012823354125
MPN: 7P0482601025
Package: 1

Technical Information

Item condition New
Manufacture name SPD type 1+2, 3 phase/3 varistors+1 spark-gap/260V Max./remote signal. (7P.04.8.260.1025)
Brand FINDER
Categories Lighting protection
Country of origin CZ
Harmonized System Code 8536 3030 00
Mounting method DIN rail (top hat rail) 35 mm
With remote signalling contact Yes
Number of conductors (without earthing) 4
Construction size 8 modular spacing
Max. continuous voltage AC 260 V
Nominal discharge surge current (8/20) 30 kA
Nominal voltage AC 230 V
Category type 2 No
Voltage protection level L-N 1.5 kV
Signalling at the device Optic
Degree of protection (IP) IP20
Voltage protection level N-PE 1.5 kV
Integrated backup fuse No
System configuration DC No
System configuration IT No
System configuration TN No
System configuration TN-C No
System configuration TN-S Yes
System configuration TT Yes
System configuration other No
System configuration TN-C-S No
Max. discharge surge current (8/20) 60 kA
Short-circuit breaking capacity (Isccr) 50 kA
Max. overcurrent protection device, parallel connection (fuse) 250 A
Max. overcurrent protection device, series connection (fuse) 125 A
Leakage-current free Yes

Packing details

Packing level 1 8012823354125

Downloads

Description

Surge protection device Mounting method: DIN rail (top hat rail) 35 mm With remote signalling contact: yes Number of conductors (without earthing): 4 Construction size: 8 modular spacing Max. continuous voltage AC: 260 V. Nominal discharge surge current (8/20): 30 kA. Nominal voltage AC: 230 V. Category type 2: no Voltage protection level L-N: 1.5 kV. Signalling at the device: Optic Protection category: IP20 Voltage protection level N-PE: 1.5 kV. Integrated backup fuse: no System configuration DC: no System configuration IT: no System configuration TN: no System configuration TN-C: no System configuration TN-S: yes System configuration TT: yes System configuration other: no System configuration TN-C-S: no Max. discharge surge current (8/20): 60 kA. Short-circuit breaking capacity (Isccr): 50 kA.