Technical data
Item condition New
Brand FINDER
Categories Lighting protection
Country of origin CZ
Harmonized System Code 8535 4000 00
Mounting method DIN rail (top hat rail) 35 mm
With remote signalling contact Yes
Number of conductors (without earthing) 2
Construction size 3 modular spacing
Voltage protection level 3.6 kV
Max. continuous voltage AC 275 V
Nominal discharge surge current (8/20) 20 kA
Nominal voltage AC 230 V
Category type 2 Yes
Voltage protection level L-N 1.2 kV
Signalling at the device Optic
Max. continuous voltage DC 350 V
Degree of protection (IP) IP20
Max. PV-voltage 420 V
Voltage protection level N-PE 1.2 kV
Integrated backup fuse No
System configuration DC No
System configuration IT No
System configuration TN Yes
System configuration TN-C Yes
System configuration TN-S No
System configuration TT No
System configuration other No
System configuration TN-C-S Yes
Max. discharge surge current (8/20) 30 kA
Max. overcurrent protection device, parallel connection (fuse) 160 A
Packing details
Packing level 1 8012823368498
Downloads
Description
Surge protection device Mounting method: DIN rail (top hat rail) 35 mm With remote signalling contact: yes Number of conductors (without earthing): 3 Construction size: 3 modular spacing Max. continuous voltage AC: 275 V. Nominal discharge surge current (8/20): 20 kA. Nominal voltage AC: 230 V. Category type 2: yes Voltage protection level L-N: 1.2 kV. Signalling at the device: Optic Max. continuous voltage DC: 350 V. Protection category: IP20 Max. PV-voltage: 420 V. Voltage protection level N-PE: 1.2 kV. Integrated backup fuse: no System configuration DC: no System configuration IT: no System configuration TN: yes System configuration TN-C: yes System configuration TN-S: no System configuration TT: no System configuration other: no System configuration TN-C-S: yes Max. discharge surge current (8/20): 30 kA.