Technical Information
Item condition |
New |
Manufacture name |
swit.act. 8-g 16 A man.act. KNX DRA |
Brand |
Gira
|
Categories |
Sensors
|
Country of origin |
DE |
Harmonized System Code |
8536 4900 00
|
Mounting method |
DRA (DIN-rail adapter) |
Rated current |
0 A |
Output power |
0 W |
Rated operating voltage |
NA V |
Bus system KNX |
Yes |
Bus system radio frequent |
No |
Bus system Powernet |
No |
Max. switching power |
0 W |
With bus connection |
No |
Max. number of switching contacts |
4 |
Number of digital inputs |
8 |
Width in number of modular spacings |
8 |
Max. switching current |
0 A |
Other bus systems |
None |
Bus system LON |
No |
Suitable for C-load |
No |
Different phases connectable |
- |
Local operation/hand operation |
Yes |
Degree of protection (IP) |
IP20 |
With LED indication |
No |
Modular expandability |
- |
Bus system KNX radio |
No |
Radio frequent bidirectional |
- |
Bus module detachable |
- |
Min. depth of built-in installation box |
0 mm |
Max. switching power LED |
NA W |
Packing details
Packing level 1 |
4010337042181 |
Description
Switching actuator, 8-gang 16 A with manual actuation for KNX DRA plus DRA switching actuators with integrated bus coupler. For switching independently controllable groups of loads. With manual switch for switching over the relay (On Off) parallel or without KNX operation. Multi-phase connection. No additional power supply required. Features: Manual actuation of the relay independent of the bus or switching position indication. NO contact or NC contact operation. Central switching function. Group feedback for reduction of bus load. Active or passive (object can be read out) cyclical feedback function. Feedback can be delayed until after the recovery of bus voltage. Logical linking function for each output. Block function can be parameterised for each channel. As an alternative, forced setting function for each output. Time functions (switch-on off delay, staircase light function – also with advance warning function). Integration in light scenes is possible, eight internal scenes at the most can be parameterised per channel. Memory function for light scenes. Elapsed operating time meter as forward backward counter with limit function (limit can be changed via bus) can be activated for each output. Input monitoring for cyclical updating with safety setting. Reactions in case of bus voltage failure and restoration can be set for each channel following an ETS programming process. Independent switching of the eight outputs. Notes : Installation on DIN top-hat rail. VDE approval in accordance with EN 60669-1, EN 60669-2-1.