Register to unlock your exclusive B2B prices and start shopping. Sign up now!
UA50-30-00RA 110-115V 50Hz / 115-127V 60Hz Contactor image 1
UA50-30-00RA 110-115V 50Hz / 115-127V 60Hz Contactor image 2
UA50-30-00RA 110-115V 50Hz / 115-127V 60Hz Contactor image 3
UA50-30-00RA 110-115V 50Hz / 115-127V 60Hz Contactor thumbnail 1
UA50-30-00RA 110-115V 50Hz / 115-127V 60Hz Contactor thumbnail 2
UA50-30-00RA 110-115V 50Hz / 115-127V 60Hz Contactor thumbnail 3

UA50-30-00RA 110-115V 50Hz / 115-127V 60Hz Contactor

In stock: No Vendor stock: No Minimal order quantity: 1
Price (excl. VAT):
98,28 € per pcs
This price is valid until 31.12.24
EAN: 3471522303899
MPN: 1SBL351024R8900
Package: 1

Technical Information

Item condition New
Manufacture name UA50-30-00RA 110-115V 50Hz / 115-127V 60Hz Contactor
Brand ABB
Categories Modular switches
Harmonized System Code 8536 4900 00
Number of normally open contacts as main contact 3
Number of normally closed contacts as main contact 0
Number of auxiliary contacts as normally open contact 0
Number of auxiliary contacts as normally closed contact 0
Rated control supply voltage at AC 50 Hz 110-115 V
Rated control supply voltage at AC 60 Hz 115-127 V
Type of electrical connection of main circuit Screw connection
Rated blind power at 400 V, 50 Hz 40 kvar
Voltage type for actuating AC

Packing details

Packing level 1 3471522303899

Downloads

Description

UA50..RA 3-pole contactors for capacitor switching, can be used in installations in which the peak current far exceeds 100 times nominal rms current. The contactors are delivered complete with their damping resistors and must be used without additional inductances (see table below). The capacitors must be discharged (maximum residual voltage at terminals ≤ 50 V) before being re-energized when the contactors are making. Their electrical durability is 250 000 operating cycles for Ue < 500 V and 100 000 operating cycles for 500 V ≤ Ue ≤ 690 V. The UA..RA contactors are fitted with a special front mounted block, which ensures the serial insertion of 3 damping resistors into the circuit to limit the current peak on energization of the capacitor bank. Their connection also ensures capacitor precharging in order to limit the second current peak occurring upon making of the main poles. The insertion of resistors allows to damp the highest current peak of the capacitor when switching on, whatever its level. The UA..RA series 3-pole contactors are of the block type design. - Main poles: 3 main poles - Control circuit: AC operated with laminated magnet circuit - Accessories: a wide range of accessories is available.