Item condition |
New |
Manufacture name |
Variable frequency drive, 230 V AC, 3-phase, 10.5 A, 2.2 kW, IP66/NEMA 4X, Radio interference suppression filter, OLED display, Local controls |
Brand |
EATON
|
Categories |
Control gear
|
Country of origin |
GB |
Width |
188 mm |
Height |
257 mm |
Depth |
239.3 mm |
With control element |
Yes |
Number of digital inputs |
5 |
Number of digital outputs |
2 |
Number of analogue inputs |
2 |
Number of analogue outputs |
2 |
Supporting protocol for LON |
No |
Number of HW-interfaces industrial Ethernet |
0 |
Number of HW-interfaces RS-232 |
0 |
Number of HW-interfaces RS-422 |
0 |
Number of HW-interfaces RS-485 |
1 |
Number of HW-interfaces serial TTY |
0 |
Number of HW-interfaces USB |
0 |
Number of HW-interfaces parallel |
0 |
Number of HW-interfaces other |
0 |
With optical interface |
No |
Supporting protocol for TCP/IP |
Yes |
Supporting protocol for ASI |
No |
Supporting protocol for PROFIBUS |
Yes |
Supporting protocol for CAN |
Yes |
Supporting protocol for INTERBUS |
No |
Supporting protocol for KNX |
No |
Supporting protocol for Modbus |
Yes |
Supporting protocol for Data-Highway |
No |
Supporting protocol for DeviceNet |
Yes |
Supporting protocol for SUCONET |
No |
Supporting protocol for other bus systems |
Yes |
Degree of protection (IP) |
IP66 |
With PC connection |
Yes |
Supporting protocol for SERCOS |
No |
Supporting protocol for INTERBUS-Safety |
No |
Mains voltage |
200-240 V |
Mains frequency |
50/60 Hz |
4-quadrant operation possible |
Yes |
Number of interfaces PROFINET |
0 |
Type of converter |
U converter |
Number of phases output |
3 |
Number of phases input |
3 |
Integrated breaking resistance |
Yes |
Application in industrial area permitted |
Yes |
Application in domestic- and commercial area permitted |
Yes |
Max. output frequency |
500 Hz |
Max. output at linear load at rated output voltage |
2.2 kW |
Max. output at quadratic load at rated output voltage |
2.2 kW |
Relative symmetric net voltage tolerance |
10 % |
Relative symmetric net frequency tolerance |
10 % |
Supporting protocol for AS-Interface Safety at Work |
No |
Supporting protocol for DeviceNet Safety |
No |
Supporting protocol for EtherNet/IP |
Yes |
Supporting protocol for Foundation Fieldbus |
No |
Supporting protocol for PROFINET CBA |
No |
Supporting protocol for PROFINET IO |
Yes |
Supporting protocol for PROFIsafe |
No |
Supporting protocol for SafetyBUS p |
No |
Max. output voltage |
250 V |
Nominal output current I2N |
10.5 A |
Supporting protocol for BACnet |
No |
Degree of protection (NEMA) |
4X |