Technical Information
Item condition |
New |
Manufacture name |
Analogue settable time relay with clock generator, 1 CO contact 10A |
Brand |
ELTAKO
|
Categories |
Relays
|
Country of origin |
CN |
Harmonized System Code |
8536 4900 00
|
Mounting method |
DIN rail |
Function |
Timer starting with impulse |
Built-in height |
58 mm |
Type of excitation |
Analogue with single function |
Width in number of modular spacings |
1 |
Number of changeover switches |
1 |
Control voltage 1 |
8-230 V |
Type of control voltage 1 |
AC/DC |
Frequency control voltage 1 |
50 Hz |
Voltage type of supply voltage |
AC/DC |
Supply voltage |
8-230 V |
1st interval unit |
Minutes/hours |
1st interval |
0.1-40 |
Switch capacity incandescent lamps |
2000 W |
Switch capacity fluorescent lamp DUO |
1000 VA |
Switch capacity fluorescent lamp inductive |
1000 VA |
Switch capacity fluorescent lamp parallel |
500 VA |
Number of contacts as normally closed contact |
0 |
Number of contacts as normally open contact |
0 |
Packing details
Packing level 1 |
4010312603116, 4010312603116 |
Packing level 2 |
4010312603116 |
Packing level 3 |
4010312603116 |
Downloads
Description
Clock generator starting with impulse, 1 CO contact potential free 10A/250V AC. 230V LED lamps up to 200W, incandescent lamps 2000W*. Standby loss 0.02-0.4 watt only. Modular devices for DIN-EN 60715 TH35 rail mounting. 1 module = 18mm wide, 58mm deep. T1 and T2 can be set separately by a second multiplier while the time base remains the same. With the Eltako Duplex technology (DX) the normally potential-free contacts can still switch in zero passage when switching 230V AC 50Hz and therefore drastically reduce wear. Simply connect the neutral conductor to the terminal (N) and L to 15(L) for this. This gives an additional standby consumption of only 0.1 Watt. Universal control voltage 8 to 230V UC. Supply voltage same as the control voltage. Time setting between 0.1 seconds and 40 hours. By using a bistable relay coil power loss and heating is avoided even in the on mode. The switched consumer may not be connected to the mains before the short automatic synchronisation after installation has terminated. The LED below the big rotary switch indicates the contact position while time-out is in progress. It blinks while the relay contact 15-18 is open (15-16 closed), and is continuously ON as long as the relay contact 15-18 is closed (15-16 open). The time base T is selected by means of the middle, latching rotary switch T. Time-base figures available are 0.1 seconds, 0.5 seconds, 2 seconds, 5 seconds, 1 minute, 2 minutes, 5 minutes, 1 hour, 2 hours and 4 hours. The total time is obtained by multiplying the timebase by the multiplier. The multiplier xT is set on the upper, latching rotary switch xT and is in the range from 1 to 10. Thus, time settings can be selected in the range from 0.1 seconds (time base 0.1 seconds and multiplier 1) and 40 hours (time base 4 hours and multiplier 10). * The maximum load can be used starting at a delay time or clock cycle of 5 minutes. The maximum load will be reduced for shorter times as follows: up to 2 seconds 15%, up to 2 minutes 30%, up to 5 minutes 60%.