Technical Information
Item condition |
New |
Manufacture name |
Three-phase energy meter, without approval |
Brand |
ELTAKO
|
Categories |
Electric meters
|
Country of origin |
CN |
Harmonized System Code |
9028 3019 00
|
Mounting method |
DRA (DIN-rail adapter) |
Width |
70 mm |
Height |
82 mm |
Depth |
58 mm |
Frequency |
50 Hz |
Max. current (Imax) |
80 A |
Width in number of modular spacings |
4 |
Degree of protection (IP) |
IP20 |
Pulse rate |
1000 Imp/kWh (kvarh) |
Pole type |
Four conductor |
Nominal voltage (Un) N-L |
230 V |
Nominal current (In) |
10 A |
Packing details
Packing level 1 |
4010312501719, 4010312501719 |
Packing level 2 |
4010312501719 |
Other Technical data
Model |
Direct measurement |
Suitable for |
Purchase/supply |
Type of indication |
Digital |
Number of positions total (counter) |
7 |
Type of meter |
Electronic |
Type of interface |
Other |
Energy type |
Effective power |
Tariff type |
Two-tariff |
Escapement mechanism |
Yes |
Calibrated |
No |
Pulse output |
Optic |
Pulse type |
S0 |
Accuracy class |
B |
Measurement type load profile |
- |
EEC40 signature |
- |
With lock code |
- |
Nominal voltage (Un) L-L |
400 V |
Downloads
Description
Maximum current 3x80A. Standby loss 0.5 watt per path only. Modular device for DIN-EN 60715 TH35 rail mounting. 4 modules = 70mm wide and 58mm deep. Accuracy class B (1%). With S0 interface. It measures active energy by means of the current between input and output. The internal power consumption of 0.5 watt active power per path is neither metered nor indicated. Like all meters without declaration of conformity (e.g. MID), this meter is not permitted for billing. 1, 2 or 3 phase conductors with max. currents up to 80A can be connected. The inrush current is 40mA. The N terminal must always be connected. The 7 segment LC display is also legible twice within a period of 2 weeks without power supply. Power consumption is shown by a bar flashing at a rate of 100 times per kWh. Designed as standard for using as double-tariff meter: Switch over to a second tariff by applying 230V to terminals E1/E2. On the right next to the display are the keys MODE and SELECT. Press them to scroll through the menu according to the operation manual. First the background lighting switches on. The display then shows the total active energy per tariff, the active energy per resettable memory RS1 or RS2, and the instantaneous values of consumption, voltage and current per phase. Error message (false): When the phase conductor is missing or the current direction is wrong 'false' and the corresponding phase conductor are indicated on the display.